Test Procedures
38
Smoke Readings
The ‘Smoke Readings’ screen displays the calculated K reading, percentage of
opacity, acceleration detection, engine speed, battery voltage, tube temperature,
heater status and the fan status.
The following information is mainly for use in Helpdesk diagnostic.
Reading
Description
User Notes
Calculated K
K value reading - 0.00
unless filter inserted or
fault
Opacity %
Opacity within sample
chamber of
Smokemeter
Accel. Det.
Signal from acoustic
sensor in smoke
chamber (typ. 0.00 with
no signal)
Engine RPM
Reading from RPM
signal input
Battery V
Battery voltage
(Approx. 12V)
Tube
Temperature
Sample chamber tube
temperature (80°C
max)
Heater Status
Sample chamber
heater status - On or
Off
Fan Status
Purge air fan status.
One in each optic box -
On or Off
Oil Temp °C
Reading from oil
temperature input
Содержание OmiSmoke