background image

11

Connections and Interfaces

5.2.2 USB Ports

The lower USB port (USB type B) at the CMC test set’s standard interface 

NET-2

 board holds a 

USB

 

port to connect 

CMC 850

 to your computer. To ensure the required EMC compatibility, we strongly 

recommend to use the OMICRON-supplied cable, only.

The upper USB port (USB type A) at the CMC test set’s standard interface 

NET-2

 board is meant for 

future use of USB peripherals, such as memory sticks, etc.

For the technical data of the USB port → chapter 7.4, "Technical Data of the Communication Ports" on 
page 20.

5.2.3 ! Button

The ! button enables you to recover from unsuccessful software image downloads or other 
emergency situations. To start a new software image download, press the 

!

button with a 

pointed tool or a paper clip while powering-up the CMC. In that case, the test set will not start as 
usual but wait for a new software image download.

5.2.4 Associate Button

The Associate button has the following functions:

• Associate with controlling computer

An Ethernet communication port enables you to communicate with any CMC available on the 
network. This may lead to dangerous situations where a user accidentally connects to a device 
located on a desk of somebody else, emitting unsafe voltages and endangering the person working 
there.

To prevent such a situation, a special mechanism is integrated into 

CMC 850

 that allows only 

“authorized” clients to control the test set. By using the 

Associate

 button, the test set is registered 

for use with a specific host PC. The test set issues voltages and current only when it is associated 
to the client requesting this. The association process can be initiated by 

OMICRON Device Link

 

(→ “Setup and Operation” on page 16). For more details about this process, refer to the Help of the 
according tool.

For the association the Ethernet hardware address (MAC) of the controlling computer is 
remembered. Consequently, if the network interface on the computer has changed, 

CMC 850

 has 

to be associated whenever the MAC address changes.

• Reset IP Configuration

If the 

Associate

 button is pressed while powering up the CMC test set, the IP configuration of the 

network interfaces is reset to factory default, which is DHCP/AutoIP for both network interfaces. It 
may be necessary to reset the IP configuration in this way to recover from settings with conflicting 
static IP addresses.

!

Associate

Содержание CMC 850

Страница 1: ...CMC 850 User Manual...

Страница 2: ...is not permitted The product information specifications and technical data embodied in this manual represent the technical status at the time of writing Subject to change without notice OMICRON elect...

Страница 3: ...esignated Use 8 4 Functionality 8 4 1 Interfaces to the Test Environment 8 4 2 Operating CMC 850 with a controlling test software 8 4 3 Time Synchronization 9 4 4 Web Interface 9 5 Connections and Int...

Страница 4: ...w Level Outputs LL out 1 6 and LL out 7 12 18 7 3 Low Level Binary Outputs ext Interf 19 7 4 Technical Data of the Communication Ports 20 7 4 1 The NET 2 Board 20 7 4 2 The NET 1C Board 21 7 4 3 The N...

Страница 5: ...instructions Only operate or even turn on CMC 850 after you have read this manual and fully understood the instructions herein CMC 850 may only be operated by trained personnel Any maloperation can re...

Страница 6: ...eed free and quick access Before connecting and disconnecting test objects verify that all outputs have been turned off Never connect or disconnect a test object while the outputs are active When disc...

Страница 7: ...a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the...

Страница 8: ...ontrolling test software Test Universe As long as the interaction with devices under test utilizes GOOSE and Sampled Values the CMC 850 test set supports all test modules of the Test Universe software...

Страница 9: ...ting with CMC test sets and the Test Universe software It serves as the clearing house for IRIG B and PPS signals regardless whether they come from an external clock or from the CMC itself CMIRIG B fa...

Страница 10: ...s enables direct remote control of CMC 850 e g for end to end testing The Ethernet ports also provide the basis for the processing of substation protocols according to the IEC 61850 standard They allo...

Страница 11: ...he network This may lead to dangerous situations where a user accidentally connects to a device located on a desk of somebody else emitting unsafe voltages and endangering the person working there To...

Страница 12: ...aiting for an emergency software image download This is the case when pressing the button while powering up the CMC test set B green LED If the yellow LED A is off the green LED B signals the followin...

Страница 13: ...n Protocol and AutoIP APIPA Automatic Private IP Addressing If the IP settings conflict with IP settings of other devices in the network it is possible to reset the test set to factory defaults DHCP a...

Страница 14: ...e the OMICRON supplied CMIRIG B interface unit as reference for the a time synchronization of the IEC 61850 bus system connect the CMIRIG B s front side connector CMC to the CMC 850 s external Interfa...

Страница 15: ...cal data Low Level Outputs LL out 1 6 and LL out 7 12 on page 18 Overload Warning in the Test Software When a low level output is overloaded the test software issues an appropriate warning Refer to th...

Страница 16: ...1 Install the test software on your computer The test software can either be the Test Universe or the RelaySimTest software Both software packages also install the OMICRON Device Link Use OMICRON Devi...

Страница 17: ...ccessible via its Web Interface Any common Web browser can be used to access CMC 850 and to make use of the embedded functions Alternative method to invoking the Web browser by the procedures describe...

Страница 18: ...connector Standard DC barrel jack 2 1 mm x 5 5 mm x 11 mm center pin is positive Output voltage 10 V 10 V Max output current 1 mA Accuracy Typical error 0 025 guaranteed 0 07 at 1 V 10 V Resolution 2...

Страница 19: ...pull up resistor Switching voltage Max 15 V Max input voltage 16 V Switch current Max 5 mA current limited min 100 A Actualization time 100 s Rise time 3 s Vextern 5 V Rpullup 4 7 k Insulation Reinfor...

Страница 20: ...Mbit s USB 1 1 compatible USB connector USB type B connect to computer USB cable USB 2 0 high speed type A B 2 m 6 ft ETH type 10 100 1000Base TX1 twisted pair auto MDI MDIX or auto crossover 1 10Bas...

Страница 21: ...ablished port active green LED ON Traffic via ETH port yellow LED is blinking ETH Power over Ethernet PoE IEEE 802 3af compliant Port capability limited to one Class 1 3 84 W and one Class 2 6 49 W po...

Страница 22: ...ransformers Using IEC 61850 9 2LE of the UCA International Users Group and to the IEC 61869 9 2016 Instrument transformers Part 9 Digital interface for instrument transformers with fixed DataSets Samp...

Страница 23: ...E 37 238 2011 Power Profile IEC PAS 61850 9 3 Communication Networks and Systems for Power Utility Automation Part 9 3 Precision Time Protocol Profile for Power Utility Automation Utility Profile Typi...

Страница 24: ...EU and the low voltage Directive 2014 35 EU Electromagnetic Compatibility EMC Emission Europe International USA EN 61326 1 EN 61000 6 4 EN 61000 3 2 3 IEC 61326 1 IEC 61000 6 4 IEC 61000 3 2 3 FCC Sub...

Страница 25: ...ICRON Open Source Download Area at www omicronenergy com opensource Open this address in your Internet browser click the Download Software button and navigate to the CMC Embedded Image directory Look...

Страница 26: ...26 CMC 850 User Manual...

Страница 27: ...a 43 59495 4444 Additionally you can find our Service Center or Sales Partner closest to you at www omicronenergy com Customer Portal Stay Informed www omicronenergy com customer The Customer Portal o...

Страница 28: ...OSE technical data 22 GPS time synchronization 8 I IP address of CMC 850 17 IP configuration 13 IP parameters 13 IRIG B time synchronization 8 L LED A B Status LED 12 LL out low level outputs 15 techn...

Страница 29: ...tware 8 communication with CMC 850 13 time synchronization technical data 23 time synchronization with IRIG B 14 U USB Port 11 USB port on NET 1C board technical data 20 21 on NET 2 board technical da...

Страница 30: ...CMC 850 User Manual 30...

Страница 31: ...ENU 1015 05 03...

Отзывы: