background image

S T E P

 1

 

Examine the existing water leader to make sure there are 
no elbows that prevent the drain stem from being fully 
inserted into the pipe. (If an elbow is present, follow 
directions on reverse  for shortening drain stem.) Insert 
U-Flow

®

 Seal into end of drain stem and tighten screws 

enough to hold the seal in place during installation. Insert 
assembled drain into existing leader pipe until flange lies 
flush on roof membrane. 

S T E P

 2

 

Alternately tighten seal compression ring screws with 
U-Flow Screw driver until hand tight. Hercules Drain body 
is correctly installed when pressure placed on drain body 
results in no vertical movement. Do not overtighten 
the screws.  

S T E P

 3

 

Secure the drain flange to the roof deck/nailer using 
a minimum of three pan-head fasteners, evenly spaced 
around the flange. The flash ing membrane must cover and 
extend past the fastener head. Flash ing membrane must 
be installed per roof membrane manufacturer’s detail.  

S T E P

 4

 

Place clamping ring over metal studs. Install stainless 
steel nut and lock washers tightening clamping ring 
against membrane flashing until secure.  
 
 

S T E P

 5

 

Install strainer dome by aligning screw holes with the 
holes in the clamping ring. Secure with screws provided.

OlyFlow

, U-Flow

®

, Hercules

®

 and RetroDrain

®

 are trademarks of OMG, Inc. 

Copyright © 2011 OMG, Inc.

M E E T S   A N S I / S P R I   R D - 1   S TA N D A R D

For Use With: 

All types of roof covers. 

Job Preparation: 

Remove existing strainer dome and 

clamping ring. Remove other existing drain components 
as required to enable Hercules Drain flange to lie flush 
on roof membrane. Remove any debris or constricting 
materials in the existing drain pipe that interferes with 
proper installation.

For technical assistance  
contact OMG at 800.633.3800.

HERCULES

®

 RETRODRAIN 

INSTALLATION INSTRUCTIONS

RP11057-30M-OP

Hercules

Drain Body

Roof Membrane

Deck

U-Flow Seal

Existing Drain
Existing Pipe

 1

Strainer

Dome

 5

Clamping

Ring

Metal Stud

 4

Flashing Membrane

(Refer to project specifications)

 3

U-Flow

Screwdriver

 2

153 BOWLES ROAD
AGAWAM, MA 01001
800.633.3800
WWW.OLYFAST.COM

Отзывы: