7. Southern Hemisphere configuration 

The south hemisphere configuration is to be used below the 
equator. In the southern hemisphere, the sky “rotates” on the 
opposite direction. For that reason, it is necessary to add an 
additional arm (C) to the mount and invert the sense of the 
timer’s movement.  
 
 

 

 

 

 

 
 
 

 

 

 
 

 
 
 
 
 
7.1.
 Release and remove the two thumbnuts (#6 Side A). 
 

 

 
 
 

 

 
7.2. 
Release and unscrew the timer screw with washer (#10) 
using a Philips-style screwdriver (not included). 

 

 

 

 

 
 
 
 
 
 
 
 

Содержание MiniTrack Quattro NS

Страница 1: ...se is strictly prohibited Subject to alterations and errors All texts illustrations and symbols are the property of nimax GmbH 69307_1_EN_Instruction Manual_REV_A 1 12 Instruction Manual Northern Hemi...

Страница 2: ...hemispheres 1 What s included A Hex Key B Polar finder C South arm 2 MiniTrack s features We recommend you familiarise yourself with all the different features of the MiniTrack s Quattro NS Side A co...

Страница 3: ...niTrack Quattro NS 4 1 The MiniTrack Quattro NS is compatible with any or tripod plates Set the mount to the tripod s plate not supplied as shown Make sure that the mount is set so that the inclinatio...

Страница 4: ...to the ball head s base Make sure to tighten it well Please notice that the ball head has two additional knobs One fixes the ball head s position in azimuth 360 deg while the other fixes the ball hea...

Страница 5: ...e star in the centre of the polar finder B field of view 5 2 To align the mount to Polaris with more precision slide the polar finder B to the polar finder holder 1 5 3 Peek through the polar finder B...

Страница 6: ...on as this might alter the timer s clock tracking rate 6 2 Pointing East When the weight of the camera setup tends to rotate the ball head in an anti clockwise direction the spring should be tensioned...

Страница 7: ...l_REV_A 7 12 7 Southern Hemisphere configuration The south hemisphere configuration is to be used below the equator In the southern hemisphere the sky rotates on the opposite direction For that reason...

Страница 8: ...it a slight push and make sure the spring is not preventing this movement 7 4 Remove the winding knob 7 and the timer screw and washer 10 as shown 7 5 Turn the winding knob 7 180 degrees form its orig...

Страница 9: ...ghtly off balance use the first positions as shown image to the left You can feel that the spring is not under a lot of tension Use the spring at its highest tension only for heavy setups and strong i...

Страница 10: ...as shown in the figure and count 4 5x its distance in the same direction to find the SCP Upon installing the supplied polar finder B we will look in more detail on how to have the star in the centre o...

Страница 11: ...Objective focal length mm 11 1 Example Camera objective 3 8 kg Objective s focal length 50mm This is within the specifications of the mount We should expect to achieve 100 50mm 2 minutes of tracking...

Страница 12: ...ons and errors All texts illustrations and symbols are the property of nimax GmbH 69307_1_EN_Instruction Manual_REV_A 12 12 13 Features Carrying capacity 4kg Balancing using spring system no counterwe...

Отзывы: