Digital Temperature 

 

 

Knowing Your Temperature Controller 

 

 

 

·

  PV: This upper display indicates the 

actual Process Value (or current 
temperature) of the bath and cannot 
be changed manually.  

·

  SV: The lower display indicates the 

Set Value or desired bath 
temperature. This Set Value is 
adjustable.  

·

  ALM 1: If this light is on, it means 

that the machine is currently heating. 
It will shut off once the desired 
temperature has been reached. 

·

  OUT: If this light is on, it means that 

the bath temperature is out of the 
preset range of 50

˚F - 160˚F. There 

is a 5

˚ hysteresis which means that 

the heating mechanism (and the 
OUT light) will go on/off based on a 
5

˚ variance. This serves as a buffer 

to protect the life of the motor 
contactor.  

·

  AT, ALM 2: Omegasonics use only.  

·

  Return Key 

Operation 

 

·

  The temperature controller is factory set at 150

˚F. 

·

  To change the Set Value, lightly press the up arrow key to increase or lightly press 

the down arrow key to decrease the value. Pressing and holding down either arrow 
key will change the displayed value rapidly.  

·

  Upon changing the Set Value, this lower display will flicker indicating the new value 

is not set. To make this value permanent, press the RETURN Key 

.  

·

  Experience shows that the optimum ultrasonic cleaning temperature for most 

applications is 120

˚F - 160˚F. 

·

  When ready to activate the heat, turn the selector switch marked 

HEAT

 to the 

ON

 

position.  

·

  The heat circuit and the ultrasound can be operated simultaneously.  

 

If increased or decreased security is desired, please contact technical support at 
Omegasonics to receive instructions.  

Содержание RESTORATION PRO 3600XW

Страница 1: ...1 Omegasonics Ultrasonic Cleaning Equipment Operation Instruction Manual RESTORATION PRO 3600XW Model OMG 5036XW 240 VAC 50 60 Hz Read all instructions thoroughly before operating this equipment...

Страница 2: ...pecific Cleaning Procedures 13 Aluminum Housings 13 Cylinder Heads 13 Electrical Components 14 Carburetors 14 Plastic Injection Molds 15 Pistons 15 DVR Cable Box 16 PPE Helmets 16 Metal Parts 17 Saw B...

Страница 3: ...d cleaning speed and consistency when compared with simple soaking or immersion with agitation Additionally the bubbles are small enough to penetrate even microscopic crevices cleaning them thoroughly...

Страница 4: ...hat contain any strong acids i e hydrochloric sulfuric or muriatic acid These chemicals will cause permanent damage to the stainless steel welds Due to the heated liquid in the tank use baskets tongs...

Страница 5: ...ing a heated deionized water source at the unit or an adjacent sink is a benefit when rinsing electrical electronic contents or contents that would show water spots General Place the machine on a leve...

Страница 6: ...oximately 86 gallons when the water level is at the midpoint of the spray bar This liquid volume does not include the liquid in the pump filter system Use this volume for calculating the amount of det...

Страница 7: ...t side of the lid towards yourself and close the lid over the tank to maximize insulation efficiency Set digital timer and temperature controls The OMG 5036XW utilizes 2 900 Watt built in silicone hea...

Страница 8: ...ect the life of the motor contactor AT ALM 2 Omegasonics use only Return Key Operation The temperature controller is factory set at 150 F To change the Set Value lightly press the up arrow key to incr...

Страница 9: ...ay The ultrasound is factory set to 15 00 minutes To adjust the preset value press the blue keys Press the up arrow key to increase or down arrow key to decrease Left most blue key corresponds to 10 m...

Страница 10: ...oing so would decrease the cavitation cleaning effects of the ultrasound How often you use the pump is dependent on what is being cleaned and the state of the water i e if the items are oily then the...

Страница 11: ...to the ON position The selector switch will spring back to the center position Before cleaning your first batch of items operate the ultrasound for fifteen 15 minutes This process is called degassing...

Страница 12: ...been set activate the ultrasound by switching SONICS to ON Cleaning times will vary depending on the temperature of the solution the number of parts to be cleaned the amount of contamination and the...

Страница 13: ...Clean the parts for another 2 5 minutes When completed rinse the parts with clean hot water that is 125 F Blow off excess moisture using compressed air or a hot air blower Cylinder Heads In the ultra...

Страница 14: ...e with free flowing de ionized water Blow off excess water with compressed air Place a bowl of 1 part Omega Deodorizer and 1 part clean water at the bottom of the drying chamber and dry the electronic...

Страница 15: ...he same temperature as the cleaning bath Blow off with compressed air Due to the heat of the metal after being removed from the bath it will dry quickly on its own flash dry NOTE Failure to completely...

Страница 16: ...complete remove residue with spray wand Submerge the box into the ultrasonic tank and clean for 1 minute Rinse thoroughly with de ionized water Use compressed air to remove excess moisture Dry for 10...

Страница 17: ...150 F Blow off the excess water using compressed air Due to the heat of the metal after being removed from the bath it will dry quickly on its own flash dry Saw Blades In the ultrasonic bath preheat 1...

Страница 18: ...If the stock is synthetic it can be cleaned with the other metal parts If it is wooden use a basket to submerge it into the bath and clean for 1 2 minutes Using a basket submerge the components into...

Страница 19: ...he inside of the tank with a clean soft cloth Do not use steel wool cleaning pads as they are too abrasive and will scratch the tank surface Rinse the tank again If the tank will not be used for a lon...

Страница 20: ...ew filter s and re install the cartridges The 50 Micron Polycarbonate Filter is the primary filter and is located on the right side of the filtration unit The Carbon Filter is the secondary oil filter...

Страница 21: ...re the responsibility of the user This warranty does not include damage or product failure which results from cavitation erosion misuse abuse or transportation damage This warranty is limited to the o...

Страница 22: ...p and water is in the tank to the middle of the spray bar a Unplug the machine from the facility power supply b Remove upper panel located on the right end of the machine c Look for the ice cube relay...

Страница 23: ...minutes to see if water moves through spray bar f If you have water flow the filters are clogged and must be replaced 5 If you are using stainless steel reusable filters follow 5a 5g a Clean outside o...

Страница 24: ...charcoal white they must be replaced 5 Call Omegasonics to order new heat blanket s Pump is causing the circuit breaker to trip 1 Likely cause is a faulty or shorted motor 2 The timer could also be sh...

Страница 25: ...vates 9 If the answer is YES the generator is the likely cause 10 If the answer is NO can you manually push in the coil to activate the ultrasound a NOTE Use an insulated screwdriver to push in the ce...

Страница 26: ...26 Float Sensor Heat Sonics Power Circuit Ice Cube Relay Contactor Contactor Contactor Breaker...

Страница 27: ...Digital Temperature Controller Digital Temp 3 Position Selector Sonics Switch 3 Position Selector 2 Position Selector Heat and Pump Switch 2 Position Selector Power Button Push Button Motor Contactor...

Страница 28: ...heat scale and mineral deposits from a variety of metals Excellent when used in an ultrasonic tank to remove rust from metal components exposed to extreme moisture and water Effectively used to remove...

Страница 29: ...ood quality rust inhibitors OmegaZyme Ideal for industrial applications cleaning oil and grease from aluminum stainless steel and titanium parts Does not remove carbon Will cause cast iron and cold ro...

Страница 30: ......

Отзывы: