TROUBLESHOOTING
Once you apply the steps described above, if you still cannot see
the Transmitter on your VC check the following items:
1. Blue LED
– The Blue LED on the Transmitter blinks every time
it transmits data. If the Blue LED is solid on it then means that
it’s trying to connect and transmit data to the access point with
no success.
2. Java Runtime Environment (JRE)
– Make sure that the
Java Runtime Environment (JRE) is running on the PC on
which the VC is installed. If the Java Runtime is not installed
on the computer the VC will not display readings from the
Transmitters. Should be 32-bit Java version 1.6 or higher.
3. Wireless Connection –
If you plan to connect on a wireless
LAN make sure that the wireless connection on your computer on
which the VC is installed is linked to the correct access point. You
may want to connect to the same access point to which the
Transmitter is connected. You can verify that by looking at the
Wireless Connection Manager on your computer.
4. Wired LAN
– If your computer is on a wired LAN on which
the correct access point is also connected, make sure that
you can reach the access point from your computer. This
can be accomplished by “pinging” the IP address of the
access point.
5. Firewall
– Make sure that the firewall is off or the exceptions are
added properly.
6. Back to AD-HOC Mode
– If you cannot find anything wrong
with your computer wireless connection and the access point,
then there is a chance that the Transmitter was not configured
correctly. To reconfigure the Transmitter you must put the
Transmitter back into the AD-HOC mode. To do this, open the
case, slide the red Power button to the OFF position. Next, press
and hold the white Default button, slide the red Power switch
back to the ON position, and release the white button once the
blue LED comes up solid. You can now follow from
Step 3.4
of
the Transmitter’s Initial Configuration section.
7. Access Point/Wireless Router
– In general, the latest/newest
access Points are better than older ones. Also, check to see if
your access point has the latest firmware installed.
SPECIFICATION
SENSOR SPECIFICATIONS
RELATIVE HUMIDITY (wTHP, wTHP2, wBTHP)
Accuracy/Range
:
±2% for 10 to 90%
±3% for 5 to 10% and 90 to 95%
±4% for 0 to 5% and 95 to 100%
Hysteresis
: ±1% RH
Non-linearity
: ±3%
Repeatability
: ±0.1%
Resolution:
0.1%
TEMPERATURE
Accuracy/Range*:
wTHP, wTHP2
±0.5°C for 5 to 45°C (±0.9°F for 41 to 113°F);
up to ±1.5°C for -40 to 5°C and 45 to 124°C
(up to ±2.7°F for -40 to 41°F and 113 to 255°F)
wTP1, wTP2
±0.5°C for 10 to 85°C (±0.9°F for 50 to 185°F);
±1°C for -40 to 10°C and 85 to 125°C
(±1.8°F for -40 to 50°F and 185 to 257°F)
wBTHP
±0.5°C for 5 to 45°C (±0.9°F for 41 to 113°F);
up to ±1.5°C for -40 to 5°C and 45 to 85°C
(up to ±2.7°F for -40 to 41°F and 113 to 185°F)
wBTP
±0.8°C @ 25ºC (±1.5°F @ 77ºF)
±4°C for -40 to 85°C (±7.2°F for -40 to 185ºF)
*NOTE: extended temp range is for Probe only,
the Controller’s operating temp is -10 to 55ºC
Resolution
: 0.1°C
BAROMETRIC PRESSURE (wBTP, wBTHP)
Accuracy/Range
:
±2 mbar for 300 to 1100 mbar @ 0 to 50ºC
±6 mbar for 300 to 1100 mbar @ -40 to 85ºC
Resolution
: 0.1 mbar
ANALOG VOLTAGE & CURRENT INPUT (wVI)
Voltage Input:
Differential; bipolar; ±100 mV, ±1 V, ±10 V
Input Impedance:
38 K ohm for voltage
Current Input:
Differential; bipolar; ±20 mA (5 ohm load)
Accuracy:
±0.1% Full Range @ 25ºC
Reading Rate
: Periodic (1 sample/update) or
continuous (3 samples/second)
Resolution
: 16 bits
THERMOCOUPLE INPUT (wTC)
Thermocouple Type (ITS 90)
:
J, K, T, E, R, S, B, C, N, L
Reading Rate
: Periodic (1 sample/update) or
continuous (3 samples/second)
METER SPECIFICATIONS
Supported Protocols (Transmitter)
: TCP/IP,
UDP, ARP, ICMP, DHCP, HTTP and FTP
Supported Protocols (VC)
:
TCP/IP, UDP, HTTP, FTP, SMTP and Telnet
WIRELESS COMMUNICATION
Standard
: IEEE 802.11 b/g
Frequency:
2.4 GHz (2402~2483.5 MHz)
Range:
60m (200') indoor line-of-site
or more depending upon sensitivity,
data rate, wireless access point and
environmental considerations
Radio Power Output Level (Class 1):
91.4 mW EIRP (19.6 dBm EIRP)
Modulation:
802.11b compatibility:
DSSS (CCK-11,
CCK-5.5, DQPSK-2, DBPSK-1);
802.11g:
OFDM (default)
Channels:
1 to 13; Channel 14 for Japan use
only and is not certified.
Channel Spacing (Bandwidth):
20 MHz
Transmission Rate (Over the Air):
802.11b:
1 to 11 Mbps for
802.11g:
6 to 54 Mbps
POWER (wSERIES AC POWER)
Power Input:
5 Vdc
Consumption:
0.7 W max
Safety Qualified AC Power Adapter
(included):
Nominal Output:
5 Vdc @ 0.6 A
Input:
100 to 240 Vac, 50/60 Hz
Back-up Alkaline Battery:
One AA 1.5 Vdc, supplied
POWER (wSERIES-CCELL)
Alkaline Battery:
Two C-CELL 1.5 Vdc, supplied
Lifetime:
Estimate of 2.4 years (wTC/wVI) and
4.3 years (wTxxP/wBxxP) with frequency of 1
reading per 1 minute
Dimensions:
96.5H x 146.3W x 50.8D mm (3.8 x 5.76 x 2"),
not including connectors or antenna
Operating Temperature:
-10 to 55ºC (14 to 131ºF), 90% RH non-condensing
AC Power Adapter:
0 to 40ºC (32 to 104ºF)
b)
Channel
– This is the Wi-Fi channel on which the
access point is accepts connections. If not sure what
channel to use, simply select Auto.
c)
Authentication
– This is the security method which the
access point is using for connections. Choose the
desired security based on the present access point settings.
Use WPA2-PSK for the most secure
connection. No security can be used to
conserve battery power. WPA2-PSK
Enterprise is not supported
d)
Passphrase
– If the authentication is WPA2-PSK, then
enter a passphrase here.
• Passphrase restricted characters include
“ ;
• The minimum characters that can be used for
Passphrase/WPA2 is 8, maximum is 63.
e)
Default Key
– This is the password if authentication is
WEP-128.
• WEP KEY can only use the following characters:
a b c d e f 0 1 2 3 4 5 6 7 8 9
.
• WEP KEY must be a length of 26 characters.
f)
DHCP
– Check this option if the Transmitter will receive
a Dynamic IP address from a DHCP server.
For initial configuration, it is recommended to
use DHCP for assigning IP Address to the
Transmitter. The IP address can be made
STATIC from the Virtual Coordinator after the
Transmitter starts communicating with it.
g)
IP Address
– Assign a STATIC IP address.
h)
Netmask
– Assign a subnet mask associated with the
STATIC IP address.
i)
Gateway Address
– This could be the IP address of
your access point or wireless router which the
Transmitter is associating with.
j)
Virtual Coordinator IP
– Assign the IP address of the
PC on which the VC is installed.
k)
Communication Protocol
– This is the protocol used
to communicate with the VC. Either TCP or UDP
protocol can be selected. UDP is default and uses less
battery power.
l)
Virtual Coordinator Port
– Readings from the sensor
(Transmitter) are sent to the VC using this port number.
Use the default UDP protocol and port
50002
unless
this port is already used on the VC. If TCP protocol is
used change this port number to 50006.
m)
Update Period
– Enter the Transmitter’s reading
transmission frequency in seconds.
n)
Save and Reboot
– Click “Save Changes”. Verify the
settings and then click “Reboot”. The webpage should
say that the Transmitter is rebooted.
If your Transmitter has a display, you should now be
able to see the sensor readings on the display.
The Transmitter stays in AD-HOC mode for a
few minutes and then goes to sleep to
conserve battery. So the step to put the device
into AD-HOC mode and to configure it using a
web page needs to be done together.
Also during this time, it is recommended to set the
“Update Period” to the default (10 seconds). Once the
Transmitter and the VC are communicating properly, the
“Update Period” can be changed to the desired value.
3.6. Getting the Readings
If the PC used to configure the Transmitter is the same as the
one running the VC, then change its IP address to the STATIC
IP address set for the VC. Start a new browser and enter
http://<IP address of PC running virtual coordinator>
If using a different PC, go to the PC running VC. Open up a web
browser and enter
http://<IP address of virtual coordinator>
Click the button that says readings. Enter the user name as
“
user
” and the password as “
12345678
”. You should be able to
see the readings.
READINGS
http://
192.168.0.105
/reading_html
Figure 8
Series
SETUP GUIDE
Wireless
Transmitter
Wi-Fi
802.11b/g Wireless Ethernet
MQS5029/0717
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly
pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every
appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for
any errors it contains, and reserves the right to alter specifications without notice.
TRADEMARK NOTICE:
®
,
omega.com
®
,
,
are Trademarks of OMEGA ENGINEERING, INC.
®
This device is marked with the international caution symbol. It is important to read the
Setup Guide before installing or commissioning this device, as the guide contains important
information relating to safety and EMC.
WARNING:
These products are not designed for use in, and should not be used for, patient-connected applications.
omega.com [email protected]
®
Servicing North America:
U.S.A.
Omega Engineering, Inc.
Headquarters:
Toll-Free: 1-800-826-6342 (USA & Canada only)
Customer Service: 1-800-622-2378
(USA & Canada only)
Engineering Service: 1-800-872-9436
(USA & Canada only)
Tel: (203) 359-1660
Fax: (203) 359-7700
e-mail: [email protected]
For Other Locations Visit omega.com/worldwide
RoHS 2 Compliant
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our
customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2017 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior
written consent of OMEGA ENGINEERING, INC.
FOR
WARRANTY
RETURNS, please have the
following information available BEFORE contacting
OMEGA:
1. Purchase Order number under which the product
was PURCHASED,
2. Model and serial number of the product under
warranty, and
3. Repair instructions and/or specific problems
relative to the product.
FOR
NON-WARRANTY
REPAIRS, consult
OMEGA for current repair charges. Have
the following information available BEFORE
contacting OMEGA:
1. Purchase Order number to cover the COST
of the repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems
relative to the product.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR)
NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING
DELAYS). The assigned AR number should then be marked on the outside of the return package and on any
correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of
13 months
from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace
period to the normal
one (1) year product warranty
to cover handling and shipping time. This ensures
that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for
any damages that result from the use of its products in accordance with information provided
by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the
company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of
OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.