13
Configuration and Programming
4.7
Retransmission Using the Analog Output
The optional Analog Output can be configured to transmit a Voltage or current signal proportional to the
Input. Select the output type in the
PRoG > IAN.1 > RNGE
menu.
For a more detailed discussion of setting up and configuring the Analog Output refer to the Platinum
Series User’s Manual (
).
4.7.1
Select an Output Type
The scaling of input readings to output voltage or current is fully user configurable.
Type
Description
0-10
0 to 10 Volts (factory default)
0-5
0 to 5 Volts
0-20
0 to 20 mA
4-20
4 to 20 mA
0-24
0 to 24 mA
4.7.2
Set Mode to Retransmission
Enable the output by setting the mode to Retransmission (
PRoG. > IAN.1 > Mode > RtRN
).
4.7.3
Set Scaling
The Retransmission signal is scaled using the following 4 parameters. The unit will display the first
scaling parameter, Rd1, after RtRN is selected.
Setting Parameters
Rd1
Process reading 1; the process reading that corresponds to the
output signal oUt1.
oUt1
The output signal that corresponds to the process value Rd1.
Rd2
Process reading 2; the process reading that corresponds to the
output signal oUt2.
oUt2
The output signal that corresponds to the process value Rd2.
Figure 11. Output Scaling