Omega OTEC IEWQ-R Series Скачать руководство пользователя страница 9

40

Installation and Maintenance

Service Manual

NO.

Malfunction
Name

Display Method of Indoor Unit

Display Method of Outdoor 

Unit

A/C status

Possible Causes 

Dual-8

Code

Display

Indicator Display (during 
blinking, ON 0.5s and OFF 
0.5s)

Indicator has 3 kinds of 
display status and during 
blinking, ON 0.5s and OFF 
0.5s

Operation
Indicator

Cool
Indicator

Heating
Indicator

Yellow

Indicator

Red

Indicator

Green

Indicator

43

Malfunction of 
phase current
detection 
circuit for 
compressor

U1

OFF 3S

and blink

13 times

During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop

Replace outdoor control panel AP1

44

Malfunction of 
voltage
dropping for
DC bus-bar

U3

OFF 3S

and blink

20 times

During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop

Supply voltage is unstable

45

Malfunction 
of complete 
units current 
detection

U5

OFF 3S

and blink

13 times

During cooling and drying
operation, the compressor will
stop while indoor fan will 
operate; 
During heating operating, 
the complete unit will stop 
operation.

Theres circuit malfunction on 
outdoor units control panel AP1, 
please replace the outdoor units 
control panel AP1.

46

The four-way
valve is
abnormal

U7

OFF 3S

and blink

20 times

If this malfunction occurs 
during
heating operation, the complete
unit will stop operation.

1.Supply voltage is lower than
AC175V;
2.Wiring terminal 4V is loosened or
broken;
3.4V is damaged, please replace 
4V.

47

Zero- 
crossing
malfunction of 
outdoor unit

U9

OFF 3S

and blink

18 times

During cooling operation,

compressor will stop while 

indoor fan will operate; during 

heating,the complete unit will 

stop operation.

Replace outdoor control panel AP1

48

49

OFF 1S

and blink

once

50

51

Compressor 

 running

52

49

Anti-

freezing 

protection 

for 

evaporator

E2

Not the error code. It’s 

the status code for the 

operation.

50

Cold air 

prevention 

protection

E9

Not the error code. It’s 

the status code for the 

operation.

51

Refrigerant 

recovery 

mode

Fo

Refrigerant recovery. The 
Serviceman operates it for 
maintenance

Содержание OTEC IEWQ-R Series

Страница 1: ...IEWQ HQ R Series High Wall Inverter Service Manual...

Страница 2: ...Summary 1 3 Removal Procedure 26 3 1 Removal Procedure of Indoor Unit 26 3 2 Removal Procedure of Outdoor Unit 35 2 Troubleshooting 2 2 1 Flashing LED of Indoor Outdoor Unit and Primary Judgement 2 2...

Страница 3: ...1 Technical Information Service Manual 1 Summary Part Technical Information Indoor Unit Outdoor Unit IEWQ036J3A RWI100 ICHQ036J3A RLH100 Remote Controller...

Страница 4: ...scharge protection overload 5 Overcurrent protection E5 OFF 3S and blink 5 times OFF 1S and blink 5 times During cooling and drying operation compressor and outdoor fan stop while indoor fan operates...

Страница 5: ...Outdoor ambient temperature sensor is open short circuited F3 OFF 3S and blink 3 times OFF 1S and blink 6 times During cooling and drying operating compressor stops while indoor fan operates During h...

Страница 6: ...wiring board XT if the voltage is higher than 265VAC turn on the unit after the supply voltage is increased to the normal range 2 If the AC input is normal measure the voltage of electrolytic capacito...

Страница 7: ...nction analysis of capacitor 29 Malfunction of module temperature sensor circuit P7 OFF 3S and blink 18 times During cooling and drying operation compressor will stop while indoor fan will operate Dur...

Страница 8: ...malfunction 5 Malfunction of mainboard rev detecting circuit 37 Desynchro nizing of compressor H7 OFF 3S and blink 7 times During cooling and drying operation compressor will stop while indoor fan wi...

Страница 9: ...t detection U5 OFF 3S and blink 13 times During cooling and drying operation the compressor will stop while indoor fan will operate During heating operating the complete unit will stop operation There...

Страница 10: ...off for 0 5s and then blinks for 10s Not the error code It s the status code for the operation 54 Undefined outdoor unit error oE Cool compressor and outdoor fan stops operation while indoor fan oper...

Страница 11: ...Possible reasons insufficient or too much refrigrant blockage of capillary an dincrease of suction temp improper running of compressor burning in or stuck of bearing damage of discharge valve malfunct...

Страница 12: ...ard broken Malfunction diagnosis process Is the wiring terminal between the temperature sensor and the controller loosened or poorly contacted Start Insert the temperature sensor tightly Yes Yes Yes Y...

Страница 13: ...on is eliminated Reinsert the wiring terminal of indoor fan It s the malfunction of main board Replace a new main board that is of the same model It s the malfunction of main board Replace a new main...

Страница 14: ...the mainboard is defined abnormal Malfunction diagnosis process Start Is there jumper cap on the mainboard Is the jumper cap inserted correctly and tightly Replace the jumper cap with the same model...

Страница 15: ...of detecting plate WIFI JF Start Is malfunction eliminated The end check if the connection wire are correctly connected Replace the detecting plate with the same model Replace the mainboard with the s...

Страница 16: ...wiring diagram Is malfunction eliminated Is malfunction eliminated Is malfunction eliminated Is malfunction eliminated Main board matches with display board Main board of IDU matches with that of ODU...

Страница 17: ...than 200V Fault with the voltage testing circuit on control panel AP1 Replace the control panel AP1 Measure the AC voltage between terminalL andN on wiring board XT power supply Voltage within 210VAC...

Страница 18: ...wires of compressor according to the electric wiring diagram and then turn on the unit Check the connection between the control board and the compressor by referring to the electric wiring diagram Che...

Страница 19: ...rature protection Is outdoor ambient temperature higher than 53 20 minutes after the complete unit is powered off Is heat dissipation of the indoor unit and outdoor unit abnormal Normal protection ple...

Страница 20: ...for compressor stopping enough Fault diagnosis process Y N Y N N Y Y N Power on the unit Is stop time of the compressor longer than 3 minutes Restart it up after 3 minutes Does startup fail Are the w...

Страница 21: ...r connected correctly Is connection sequence right Is the connection made in clockwise direction Connect the wires correctly Replace the control panel AP1 If the fault is eliminated Replace the compre...

Страница 22: ...process 20 minutes after the complete unit is powered off Is the terminal FA for the electronic expansion valve connected correctly Connect the wires correctly Resistances between the first four pins...

Страница 23: ...pment operate normally before the failure occurs The AP1 voltage detection circuit is at fault Check wiring inside of the indoor and outdoor units Are wires broken Check the communication circuit of t...

Страница 24: ...e main board AP1 of the outdoor unit If the fault is eliminated Is the connection right Check the wiring of the indoor and outdoor units with reference to the wiring diagram Correctly connect the corr...

Страница 25: ...swing louver is fully open Check if the capacity output of outdoor unit is equal to the capacity demand of indoor units Check if the indoor outdoor filters or radiating fins are dirty or blocked Clea...

Страница 26: ...d for details Malfunction of compressor Compressor Can t operate Refer to point 5 of maintenance method for details 2 3 Troubleshooting for Normal Malfunction 1 Air Conditioner Can t be Started Up 2 P...

Страница 27: ...ipe Replace drain pipe Wrapping is not tight Water leaking from the pipe connection place of indoor unit Wrap it again and bundle it tightly 5 Compressor Can t Operate Possible causes Discriminating m...

Страница 28: ...e refrigerant completely before removal 3 1 Removal Procedure of Indoor Unit Steps Procedure 1 Before disassembly of the unit 2 Remove filter panel clasps filter Axonometric drawing for the complete u...

Страница 29: ...move panel 5 Remove horizontal louver display clasp panel horizontal louver Remove 2 screws fixing display and then remove the filter Pull the clasps at both sides slightly and then remove the panel R...

Страница 30: ...screw cap screw front case Procedure Steps Remove screws fixing the top cover of electric box Remove the screw fixing detecting plate and then remove the detecting plate Note The position of detectio...

Страница 31: ...e 8 Remove earthing wire 9 Remove electric box cover screw clasp clasp electric box cover Remove earthing screws and then remove the earthing wire Loosen clasps at the left side of electric box Loosen...

Страница 32: ...l a b c Procedure Steps 10 Remove temperature sensor 11 Remove electric box temperature sensor screw electric box Pull out the indoor temperature sensor Pull out 6 sockets on PCB board Pull out two sc...

Страница 33: ...rd water tray connection position for indoor and outdoor units pipe stopping plate screw screw damping board Pull the water tray upwards and then remove the water tray Separate the connection pipe bet...

Страница 34: ...te of motor screw evaporator screw Remove screws between evaporator and bottom case Turn over the indoor unit and adjust the pipe line to the position as shown by the broken line Lift up the evaporato...

Страница 35: ...tion and Maintenance Service Manual a Procedure Steps b c 18 Remove cross flow blade and motor blade motor Remove screws fixing cross flow blade and motor Remove the motor sub assy Separate two cross...

Страница 36: ...71 Installation and Maintenance Service Manual a b Procedure Steps 19 Remove cushion rubber cushion rubber Remove the cushion rubber on cross flow blade Remove the cushion rubber from the base...

Страница 37: ...e and then remove the top panel 2 Remove grille and panel Remove the 2 screws connecting the grille and the panel and then remove the grille top pane grille Handle Steps Procedure Valve cover Twist of...

Страница 38: ...ront side panel the screws connecting the panel with the chassis and the motor support and then remove the panel 3 Remove and right side plate Right side plate Remove the screws connecting the right s...

Страница 39: ...rminals and then pull the electric box upwards to remove it Remove the 4 tapping screws fixing the motor disconnect the leading wire insert of the motor and then remove the motor Remove the 2 tapping...

Страница 40: ...sy Isolation sheet and Isolation sheet Remove the 3 screws fixing the isolationsheet and then remove the Isolation sheet 8 Remove 4 way valve assy and electronic expansion valve Discharge the refriger...

Страница 41: ...ove the compressor Remove the screws connecting the support condenser and condenser assy and then remove the support condenser 9 Remove compressor compressor 10 Remove condenser sub assy a support b D...

Страница 42: ...Tf Tcx1 8 32 Ambient temperature Fahrenheit display temperature o F Fahrenheit o F Celsius o C Fahrenheit display temperature o F Fahrenheit o F Celsius o C Fahrenheit display temperature o F Fahrenhe...

Страница 43: ...llowing steps A Cut the pip Confirm the pipe length according to the distance of indoor unit and outdoor unit Cut the required pipe with pipe cutter B Remove the burrs Remove the burrs with shaper and...

Страница 44: ...88 33 10 63 72 2 439 111 0 737 5 63 46 34 10 2 73 2 358 112 0 717 4 60 23 35 9 779 74 2 28 113 0 697 3 57 18 36 9 382 75 2 206 114 0 678 2 54 31 37 9 003 76 2 133 115 0 66 1 51 59 38 8 642 77 2 064 1...

Страница 45: ...983 5 84 61 34 13 59 73 3 144 112 0 956 4 80 31 35 13 04 74 3 04 113 0 93 3 76 24 36 12 51 75 2 94 114 0 904 2 72 41 37 12 76 2 844 115 0 88 1 68 79 38 11 52 77 2 752 116 0 856 0 65 37 39 11 06 78 2 6...

Страница 46: ...62 11 32 101 3 22 15 362 9 24 51 41 63 10 93 102 3 13 14 342 8 25 49 19 64 10 54 103 3 04 13 323 9 26 47 08 65 10 18 104 2 96 12 306 2 27 45 07 66 9 83 105 2 87 11 289 6 28 43 16 67 9 49 106 2 79 10 2...

Страница 47: ...OMEGAIEWQ HQ High Wall Inverter Service Manual info otecvrf com www otecvrf com info omegavrf com www omegavrf com IEWQ HQ I3A SM1R0622...

Отзывы: