background image

SECTION 4 - LASER SIGHT ACCESSORY

4.1 – Warnings and Caution

You may receive harmful laser radiation exposure if you do
not adhere to the warnings listed below:

• USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF

PROCEDURES OTHER THAN THOSE SPECIFIED IN THIS GUIDE MAY
RESULT IN HAZARDOUS RADIATION EXPOSURE.

• DO NOT LOOK AT THE LASER BEAM COMING OUT OF THE LENS OR

VIEW IT DIRECTLY WITH OPTICAL INSTRUMENTS – EYE DAMAGE CAN
RESULT.

• USE EXTREME CAUTION WHEN OPERATING THE LASER SIGHT

ACCESSORY.

• NEVER POINT THE LASER ACCESSORY AT A PERSON.

• KEEP THE LASER SIGHT ACCESSORY OUT OF REACH OF ALL

CHILDREN.

Do not attempt to open the laser sight accessory. There are no
user serviceable parts inside.

4.2 – Operating the Laser Sight Accessory

The laser sight accessory screws onto the front of the transmitter sensor head.
This accessory is only used for alignment of the transmitter head to the target
area. After the alignment process, the accessory has to be removed from the front
of the transmitter head before temperature measurement is made.

The laser sight accessory is powered from a small, compact battery pack
(included with the accessory). Connect the battery pack to the accessory using
the cable provided. Aim at the target, and turn on the battery power using the
slide switch on the battery pack. Adjust the sensor head position so that the laser
beam points to the center of the target area. Turn off the battery pack, and
remove the laser sighting accessory from the sensor head (Fig 4-1).

CAUTION:

WARNING:

Laser Sight Accessory

4

7

Содержание OS137 SERIES

Страница 1: ...ontact Infrared Temperature Sensor Transmitter MADE IN omega com e mail info omega com For latest product manuals omegamanual info User sGuide Shop online at CAUTION This product is not intended for m...

Страница 2: ...ged by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0 800...

Страница 3: ...1 Section 2 Installation 1 2 1 Unpacking 1 2 2 Electrical Connection 2 Section 3 Operation 3 3 1 Measuring Temperature 3 3 2 Ambient Temperature 4 3 3 Atmospheric Quality 4 3 4 Alarm Setting 6 Sectio...

Страница 4: ...ring Diagram 2 2 2 Alarm Output Wiring Diagram 2 3 1 Optical Field of View 3 3 2 Location of Emissivity Alarm Adjust and Alarm Switch 3 3 3 Mounting Bracket OS137 MB 4 3 4 Air Purge Collar OS137 AP 4...

Страница 5: ...able is a multi conductor 24 AWG stranded wire with the rating of 600 VDC 205 C 401 F Teflon insulation Power must be disconnected before making any electrical connections The recommended power supply...

Страница 6: ...he packing list and verify that you have received all your equipment If you have any questions about the shipment please call OMEGA Customer Service at 1 800 622 2378 or 203 359 1660 We can also be re...

Страница 7: ...ng Diagram Figure 2 2 Alarm Output Wiring Diagram Accessories Model No Description OS137 MB Mounting Bracket OS137 WC Water Air Cooling Jacket with Built in Air Purge Collar OS137 AP Air Purge Collar...

Страница 8: ...on the target surface Then put back the End Cap Make sure the output load is within the product specification Figure 3 1 Optical Field of View Figure 3 2 Location of Emissivity Alarm Adjust and Alarm...

Страница 9: ...ture For example it takes about 30 minutes for the transmitter to stabilize from the 25 C to 50 C 77 F to 122 F ambient temperature 3 3 Atmospheric Quality Environments with smoke dust and fumes dirty...

Страница 10: ...NURL 2 5 0 1 WIDE DIMENSIONS mm in 1 20 UNEF 127 5 0 1 83 m 6 ft 42 4 1 67 25 4 1 0 DIMENSIONS mm in 128 6 5 062 7 9 0 312 41 2 1 625 1 20 UNEF 9 5 3 8 1 20 UNEF BUILT IN AIR PURGE COLLAR APPLY CLEAN...

Страница 11: ...2 Set the Slide Switch on the main board to the Alarm position 2 Measure the analog output and adjust the Alarm Potentiometer until the output reads 10 4 mA which is 40 204 C 400 F of the temperature...

Страница 12: ...rviceable parts inside 4 2 Operating the Laser Sight Accessory The laser sight accessory screws onto the front of the transmitter sensor head This accessory is only used for alignment of the transmitt...

Страница 13: ...WITCH BATTERY PACK POWER SUPPLY OS137 Dimensions mm in OUTPUT 1 mW WAVELENGTH 630 670 nm CLASS II 2 LASER PRODUCT COMPLIES WITH FDA 21CFR 1040 10 EN60825 1 11 2001 LASER RADIATION DO NOT STARE INTO BE...

Страница 14: ...mV F Output Load Requirements Min Load 0 to 5 Vdc 2 K Ohms Min Load 0 to 10 Vdc 4 K Ohms Max Load 4 to 20 mA Power Supply 4 20 mA Min Load 10 mV Deg 10 K Ohms Min Load K T C 100 K Ohms Operating Ambie...

Страница 15: ...er Less than 5 mm Beam Divergence Less than 2 mrad Operating Temperature 0 to 50 C 32 to 122 F Operating Relative Humidity Less than 95 RH non condensing Power Switch ON OFF Slide Switch on the batter...

Страница 16: ...ron 0 94 Iron and steel excluding stainless rusted iron plate 0 69 Iron and steel excluding stainless polished steel 0 07 Iron and steel excluding stainless polished steel oxidized at 600 C 1112 F 0 7...

Страница 17: ...soda 0 85 to 0 95 Marble polished light gray 0 93 Paints lacquers and varnishes Black matte shellac 0 91 Paints lacquers and varnishes aluminum paints 0 27 to 0 67 Paints lacquers and varnishes flat...

Страница 18: ...OS137 Series Miniature Non Contact Infrared Temperature Sensor Transmitter 6 13 NOTES...

Страница 19: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Страница 20: ...ity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Отзывы: