![Omega OME-PCI-1002 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/omega/ome-pci-1002/ome-pci-1002_user-manual_4006654009.webp)
1.4.3 D/I and D/O
•
Channels: 16 channels DI, 16 channels DO
•
DO: Digital output port
Output level: TTL compatible
Output current:
Ioh = 0.5mA, Iol = 8mA
•
DI: Digital input port
Input level: TTL compatible
Input current: 50uA (max)
1.4.4 A/D Trigger Methods
•
Trigger-methods :
1.
Software trigger
2.
Pacer trigger: 16-bit programmable timer/counter
3.
External trigger: Pre-trigger, Post-trigger, external Pacer trigger
External trigger
t
Start End
Post-trigger mode
CHn
External trigger
Start End
CHn
Pre-trigger mode
t
t
Start End
Normal trigger mode
CHn
Pacer or software trigger
t
End
Start
External pacer trigger mode
External trigger
CHn
Figure 1-2. Trigger methods of OME-PCI-1002.
9