background image

Rev. 2013-12-16 

 

 

 

OM-ESW-104, OM-ESW-105 and OM-ESW-108 Instruction Sheet 

 

This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only. 

 

PACKAGE CONTENTS 

One OM-ESW-104, OM-ESW-105 or OM-ESW-108 

 

UNPACKING 

Remove all the equipment from the packaging, and store the packaging in a safe place.  File any damage claims with the 

carrier. 

 

APPLYING POWER (Top View) 

 

 

 

 

Unscrew & Remove the DC Voltage Input Plug from the top header. 

Install the DC Power Cables into the Plug observing polarity as shown above. 

Plug the Voltage Input Plug back into the top header. 

Tightening torque for the terminal block power plug is (

0.22 Nm) 2 lbs/in.

 

All LED’s will flash ON momentarily. 

Verify the Power LED stays ON (GREEN). 

 

Note:

  Either V

1

 or V

2

 can be connected to power for minimal operation.  For redundant power operation, V

1

 and V

2

 

plugs must be connected to separate DC Voltage sources.  Use wire sizes of 16-28 gauge.  The power cord should 

be  limited  to  less  than  10  meters  in  order  to  ensure  optimum  performance.  For  OM-ESW-108  use  60/75°C  rated 

copper wire. For OM-ESW-104 and OM-ESW-105 use 95°C rated copper wire. 

 

Note: 

The large #6 mounting/grounding screws located on the back plate must not be longer than 1/4". 

 

Recommended Power Supply

:  

DC 24V/1.3Amp min. 

WARNING

ALERTE – 

Risque D’explosion – Remplacement d’un composant peut empêcher la conformité de Classe I, Division 2.

ALERTE – 

Risque D’explosion – Ne débranchez pas tant que le circuit est sous tension sauf si la zone est connue pour 

être non dangereux.

ALERTE – 

Risque D’explosion – Ne pas remplacer le dispositif que l’alimentation est coupée ou que la zone est connue

pour être non dangereux.

 – Explosion Hazard – Substitution of any component may impair suitability for Class I, Division 2. 

WARNING

 – Explosion Hazard – Do not disconnect while circuit is live unless area is known to be non-hazardous. 

WARNING

 – Explosion Hazard – Do not replace the device unless power has been switched off or the area is known to 

be non-hazardous.  
 

To download the User Manual please visit the following location:

http://www.omega.com/manuals/manualpdf/M5163.pdf 

 

 

 

 

LED  Color 

Description 

 

 ON 

 Power is Applied. 

 

 OFF 

 Power is OFF. 

 

LNK 

/ACT 

 

 ON 

 Link established, no Activity on                

cable. 

 BLINKING  Link established, Activity on cable. 
 OFF 

 No link activity on cable. 

SPD   ON 

 LINK is 100Mbps. 

 

 OFF 

 Link is 10Mbs. 

Отзывы: