7
TABLE N°1: Energy Consumption
Energy consumption
Burners Gas
type
Pressure (kPa)
Injector (mm)
Mj/hr
Watts
Auxiliary
Natural
U-LPG
1.0
2.75
0.90
0.54
4
4
3500W
Semi-rapid
Natural
U-LPG
1.0
2.75
1.18
0.70
7
7
Rapid
Natural
U-LPG
1.0
2.75
1.55
0.92
12
12
Wok
Natural
U-LPG
1.0
2.75
1.8
1.02
16
14.8
Test the operation of the cooker before leaving
Note: These burners have no aeration adjustment.
Check correct operation of the ignitions system and operation of the regulator and operation of the burners individually and in
combination. Burner flames should be clear blue, with no yellow tipping. If the burners show any abnormality check that the
burners are correctly located. If satisfactory performance cannot be obtained, contact Omega service.
Important
Before leaving instruct the owner in the use of the cooker it should be expressly noted that we cannot accept any liability for
direct or indirect damage caused by wrong connection or improper installation. When being repaired, the appliance must
always be disconnected from the mains supply; if required, notify our customer service.
TABLE N°2: GAS BURNER DIMENSION
Burner
Dimension (mm)
Auxiliary
Ø 50
Semi-rapid
Ø 70
Rapid
Ø 95
Wok Ø