background image

 

 

      

 

GAS CONNECTIONS 

 

LOCAL AUTHORITY REQUIREMENTS 

Check Gas Type and specifications plate placed on the bottom face of the unit. All gas fitting work, service and 
repairs can only be performed by an authorized person in accordance with the current edition of AS5601 and 

local gas regulations.  Failure to comply with this condition will render the warranty invalid.  Always unplug the 
appliance before carrying out any maintenance operations or repairs.  The walls of the units must not be higher 
than work top and must be capable of resisting temperatures of 75 above temperature.  Do not install the 
appliance near flammable materials (eg. curtains).  The final act of any installation or gas type conversion must 
be the full testing of this appliance, which includes leak testing, ignition of each burner and the functionality of 

the burners separately and together.   
 

INSTALLATION 

The appliance is predisposed and adjusted to operate with the gas indicated on the specifications plate 
(normally NG) applied onto the appliance. Please see gas rates summary information on the previous page. 
If the appliance must be operated with a gas different than that indicated on the plate, it is necessary to execute 
the following operations: 
-Gas connection including regulator (NG) or test point nipple adaptor (LPG) to be changed. 
-Replacement of the injectors. 
-New gas label attached stating gas type. 
-Adjustment of minimum setting. 
 
 
 
 

GAS CONNECTION  

The connection must be made by a qualified gas fitter according to the relevant standard.  The gas connection 
is positioned on the left hand side (from front), 40mm in from the back edge. 
The fitting (fig. 6.1) is made up of: 
1 elbow fitting “A” 
1 gaskets “F” 
1 LPG test point nipple adaptor “B” 
The hob must be installed in a room with adequate ventilation (see installation section). 

 

N.G.:  

Fit the supplied NG regulator to the elbow fitting “A” using two spanners (note orientation of the NG regulator 

gas flow). 
Connect the other side of the NG regulator to the gas inlet pipe with the correct ½” BSPT thread connector 
using two spanners.

 

 

L.P.G.: 
Connect the LPG test point nipple adaptor “B” to the cooking hob inlet “A” and then connect to the gas inlet 
pipe with the correct ½” BSPT thread connector (or using the appropriate adaptor) using two spanners.  
Connect the other end of the pipe to the cylinder pressure regulator. 

 

Содержание OCG61XA

Страница 1: ...INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS FOR OMEGA 4 BURNER GAS COOKTOP Models Included OCG61XA IMBERLEY INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS...

Страница 2: ...lation 8 9 Operating Instructions 10 Cleaning 10 11 It is important that you retain these instructions proof of purchase as well as other important documents about this product for future reference Du...

Страница 3: ...mall children are nearby It is recommended that children are kept away from the cooktop at all times 6 This appliance is not suitable for connection with a hose assembly 7 If the electrical supply cor...

Страница 4: ...d on the front face e g 1 8 for 1 80mm injector Semi rapid Burners Wok Burner Auxiliary Burner Table of recommended pot sizes for each burner type Control Knob functions are displayed around each knob...

Страница 5: ...the previous page If the appliance must be operated with a gas different than that indicated on the plate it is necessary to execute the following operations Gas connection including regulator NG or t...

Страница 6: ...oapy solution and a brush but never a naked flame OPERATIONS TO BE PERFORMED WHEN CONVERTING GAS TYPES This operation can only be performed by an authorized person Remove the gratings and the burner c...

Страница 7: ...ectrical connection can be found centrally along the back rear edge of the appliance INSTALLATION This cooktop must be connected to a 220 240V 50Hz power supply It is earthed via the cord Before carry...

Страница 8: ...on the power point match the appliance s power rating INSTALLATION Note These tops are designed to be fitted into kitchen fixtures measuring 600 mm in depth In order to install the cooker top into the...

Страница 9: ...an underneath the hob is forbidden PREPARING PLACING THE HOB FOR INSTALLATION Every cooker top is provided with a set of tabs for fitting to the unit with thickness from 3 to 4 cm and a seal with adhe...

Страница 10: ...ls section for recommended sizing When cooking always try to use a pot or pan with a flat base Pots pans with an uneven or curved base will cause the burner to run inefficiently and will take longer t...

Страница 11: ...rner flame distributor F and the cap C are correctly positioned fig 6 Failure to do so can cause problems with ignition and also the way in which the burner operates Check that the electrode S is alwa...

Страница 12: ...division of Shriro Australia Pty Ltd 104 Vanessa St Kingsgrove NSW 2208 IN AUSTRALIA 1300 795 572 IN NEW ZEALAND 09 415 6000 www omegaappliances com au IM Ref OCG61XA 06 2015 02FC FOR INDOOR USE ONLY...

Отзывы: