Automatic Rearming Notes:
• Turning on the vehicle’s ignition cancels Automatic Rearming.
• Opening a door will suspend the 90 second countdown.
• All protected zones must remain non-violated during the 90 second Automatic
Rearming period. For example, if a vehicle door is opened during the 90 sec-
ond period, the countdown will stop. When the door is closed, the system re-
sets and starts a new 90 second countdown period.
• The Automatic Rearming sequence is indicated by a fast flashing Red Status
Indicator Light, unless the system has been activated, in which case a Zone
Violation Code will flash instead (pages 21-22). The ignition switch must be
turned on to erase a violation code.
• If the system is disarmed while it is activated (siren sounding and lights flashing)
Safety Disarm will cancel the Automatic Rearming for that disarming operation
only. The next time the system is armed, Automatic Rearming will be initiated
upon the subsequent disarming.
Driver’s Door Priority Unlocking Notes:
• There is no time limitation for the second pressing of the “Disarm/Unlock”
button. Once the button is pressed and released to Disarm the system, every
subsequent pressing of the “Disarm/Unlock” button will produce the “unlock
all doors” output, the single siren chirp and parking and dome light illumina-
tion period. When the system is next armed, by any of the three methods, the
operation is reset so the next use of the “Disarm/Unlock” button will result in
the system Disarming and producing the “unlock driver’s door only” output.
• When disarming a system configured for Driver’s Door Priority, the user has
the option of Silent Disarming (by pressing twice the 2nd Channel Output but-
ton), and then pressing the “Unlock/Disarm” button, if needed, to unlock all of
the doors.
Emergency Override:
In the event that your transmitter is lost, damaged, or its batteries have become
exhausted, the Valet Switch and the vehicle’s ignition key may be used to disarm
the system. These Emergency Override instructions reflect a default setting of “1
press”; but be aware that the “SecureCode” programmable feature, described on the
following page, allows the owner to customize the number of Valet Switch presses
needed for the Emergency Override.
DISARMING BY EMERGENCY OVERRIDE
Page 36
#28 Open Door Warning Upon Arming:
Default Off
When this feature is programmed to operate, if one of the vehicle's doors is open
when the system is armed using the remote transmitter, the siren will chirp 3 times
instead of once when arming the system with the transmitter.
Programming Open Door warning Upon Arming:
Follow Steps 1 to 4 on
page 25; at Step 4 the Valet Switch will be pressed and released twenty eight times.
The system’s response will be twenty eight siren chirps, and the Status Light
flashing twenty eight times, pausing, then repeating. Within 10 seconds, press and
release the transmitter’s "Arm/Lock" button to turn on Open Door Warning Upon
Arming (the siren will chirp once) or the "Disarm/Unlock" button to turn this
feature off (the siren will chirp twice).
#29 “III” Button Operates Remote Panic:
Default On
This feature changes the remote transmitter's operation of the Remote Panic feature
and the 3rd channel output. When this feature is turned off, pressing the
transmitter's “
III
” button for 3 seconds will operate the 3rd channel output. The
remote panic feature can still be operated, by pressing either the “Arm/Lock” or
“Disarm/Unlock” button for 3 seconds to activate it. Once activated, pressing either
of these buttons will deactivate the remote panic feature. When button “
III
” is
programmed to operate the 3rd channel output, Remote Panic can be activated by
pressing together the “
II
” and “
III
” buttons.
Programming “III” Button Operates 3rd Channel Output:
Follow Steps 1
to 4 on page 25; at Step 4 the Valet Switch will be pressed and released twenty nine
times. The system’s response will be twenty nine siren chirps, and the Status Light
flashing twenty nine times, pausing, then repeating. Within 10 seconds, press and
release the transmitter’s "Arm/Lock" button to turn on the “
III
” Button Operates 3rd
Channel Output (the siren will chirp once) or the "Disarm/Unlock" button to have
the “
III
” button operate the Remote Panic feature (the siren will chirp twice).
#30 Remote Start Run Time 10 Or 20 Minutes:
Default 10 Minutes
This feature sets the period of time that the engine will run after being remotely
started. If the engine is not stopped by transmitter or a safety circuit violation, the
engine will automatically stop upon the expiration of the selected time period.
Programming 10 or 20 Minute Run Time:
Follow Steps 1 to 4 on page 25;
at Step 4 the Valet Switch will be pressed and released thirty times. The system’s
response will be thirty siren chirps, and the Status Light flashing thirty times,
pausing, then repeating. Within 10 seconds, press and release the transmitter’s
"Arm/Lock" button to configure the system for 20 minute remote start engine run
time (the siren will chirp once) or the "Disarm/Unlock" button to configure the
system for 10 minute run time (the siren will chirp twice).