SPECIFICATIONS

 

(ultrasonic)

 

Step

 

Two

 

Ultrasonic

 

Switch

 

(LVU

150

 

series):

  

The

 

Ultrasonic

 

level

 

switch

 

generates

 

a

 

1.5

 

MHz

 

ultrasonic

 

wave

 

from

 

a

 

miniature

 

piezoelectric

 

transducer

 

located

 

on

 

one

 

side

 

of

 

the

 

gap

 

in

 

its

 

sensing

 

tip.

  

Another

 

piezo

 

transducer

 

located

 

on

 

the

 

other

 

side

 

of

 

the

 

gap

 

acts

 

as

 

a

 

microphone,

 

picking

 

up

 

the

 

sound.

  

When

 

liquid

 

enters

 

the

 

gap

 

in

 

the

 

sensing

 

tip,

 

the

 

audio

 

level

 

changes.

  

 

LVU

152

R

 

&

 

LVU

153

R

 

LVU

150

R

 

&

 

LVU

151

R

 

 

LVU

152

G

R

 

&

 

LVU

153

G

R

 

LVU

150

G

R

 

&

 

LVU

151

G

R

 

 

The

 

sensor

 

should

 

be

 

installed

 

so

 

that

 

the

 

liquid

 

will

 

drip

 

out

 

of

 

the

 

gap

 

when

 

the

 

sensor

 

becomes

 

dry.

 

LVU

150

 

Series

  

Specifications:

 

Sensor

 

material:

  ‐

150/

152:

 

PP

 

 

151/

153:

 

PFA

 

Cable

 

jacket

 

mat’l:

  ‐

150/

152:

  

PP

 

 

151/

153:

  

PFA

 

Configurations:

 

Part

 

Number

 

Length

 

Material

  

(body)

 

Material

  

(cable)

 

Cable

 

Length

 

LVU

150

R

 

Short

 

(3”)

 

Polypropylene

 

Polypropylene

 

10’

 

LVU

150

G

R

 

Short

 

(3”)

 

Polypropylene

 

Polypropylene

 

10’

 

LVU

151

R

 

Short

 

(3”)

 

PFA

 

FEP

 

10’

 

LVU

151

G

R

 

Short

 

(3”)

 

PFA

 

FEP

 

10’

 

LVU

152

R

 

Long

 

(4.5”)

 

Polypropylene

 

Polypropylene

 

10’

 

LVU

152

G

R

 

Long

 

(4.5”)

 

Polypropylene

 

Polypropylene

 

10’

 

LVU

153

R

 

Long

 

(4.5”)

 

PFA

 

FEP

 

10’

 

LVU

153

G

R

 

Long

 

(4.5”)

 

PFA

 

FEP

 

10’

 

Note:

 

all

 

ultrasonic

 

level

 

switches

 

are

 

available

 

with

 

longer

 

lengths

 

cable

 

of

 

25’

 

and

 

50’.

  

For

 

25’

 

of

 

cable,

 

add

 

(

25)

 

to

 

the

 

end

 

of

 

the

 

part

 

number

 

and

 

for

 

50’

 

of

 

cable,

 

add

 

(

50)

 

to

 

the

 

end

 

of

 

the

 

part

 

number.

  

Example,

 

LVU

150

R

25

 

will

 

have

 

25’

 

of

 

cable.

 

 

Содержание LVF-210A Series

Страница 1: ...1...

Страница 2: ...2...

Страница 3: ...itches with either Omega Engineering controllers LVCN 100 series or LVCN 120 series or interface directly to another controller or PLC Table of Contents Specifications Common 4 Ultrasonic Switch LVU 1...

Страница 4: ...relay Contact rating 60VA Contact output Selectable NO NC Process temp F 40 to 176 C 40 to 80 Pressure 150 psi 10 bar 25 C derated 1 667 psi 113 bar per C above 25 C Sensor rating NEMA 6 IP68 Cable ty...

Страница 5: ...sensor becomes dry LVU 150 Series Specifications Sensor material 150 152 PP 151 153 PFA Cable jacket mat l 150 152 PP 151 153 PFA Configurations Part Number Length Material body Material cable Cable...

Страница 6: ...the sensor and void the warranty When powering up the LTU 101A series the start up procedure requires the switch to cycle through a wet condition for 1 2 second in order to determine an initial reson...

Страница 7: ...ng To wire the maintenance output wire to an LED follow the wiring diagram below The Yellow wire is connected to the LED and a 2 2k resistor in series and referenced back to the of the power supply Se...

Страница 8: ...mersed in liquid the light beam will refract out into the liquid instead of being reflected to the photo transistor indicating a wet condition The LVF 210A series is designed as a leak detection switc...

Страница 9: ...3 4 R LVF 211A R Short 3 PFA PFA 3 4 NPT 3 4 NPT LVF 211A G R Short 3 PFA PFA 3 4 R 3 4 G LVF 212A R Long 4 5 Polypropylene Polypropylene 3 4 NPT 3 4 NPT LVF 212A G R Long 4 5 Polypropylene Polypropy...

Страница 10: ...n LVC 152 series level switch Acetone 21 Acetoaldehyde 22 2 Acetyl methyl hexyl ketone 28 Alcohol 16 to 31 Ammonia 15 to 25 Acetic acid 4 1 to 6 2 Butyl chloride 9 6 Barium chloride 9 to 11 Benzene 2...

Страница 11: ...and 50 For 25 of cable add 25 to the end of the part number and for 50 of cable add 50 to the end of the part number Example LVC 152 R 25 will have 25 of cable Testing Tip The LVC 152 series sensor l...

Страница 12: ...LVU 150 series and LVF 210A series sensors are available in two different wetted materials Models LVU 150 LVU 152 LVF 210A and LVF 212A are made of Polypropylene PP Models LVU 151 LVU 153 LVF 211A an...

Страница 13: ...a single internal relay The normally open NO or normally closed NC operation is user selected based on the desired system control Always design a fail safe system that accommodates for the possibility...

Страница 14: ...he entire length of track The LVM 10 series may be installed through the top wall of any tank using a standard 2 NPT tank adapter If no tank top installation is available Omega Engineering s side moun...

Страница 15: ...arefully remove the outer layer of insulation from the last 1 1 4 of the sensor s cable Unwrap and discard the exposed foil shield from around the signal wires leaving the drain wire attached if desir...

Страница 16: ...uits and a resistor capacitor RC for AC circuits Catch Diode Always use stepper relays between the sensor and external loads For DC circuits use a catch diode such as 1N4148 shown on left Refer to the...

Страница 17: ...or White wires Complete the circuit by connecting the Green to VDC power or White to VDC power see illustration below Sensor Power RED BLK wires 36 VDC Max 5 1mA Dry 22 1mA Wet 8 1mA Dry LTU 101A seri...

Страница 18: ...e Negative to complete the circuit Sensor Power RED BLK wires 36 VDC Max 30 VDC Max for LTU 101A series 5 1mA Dry 22 1mA Wet 8 1mA Dry LTU 101A series only Relay Rating GRN WHT wires 60 VA Normally Op...

Страница 19: ...as steel wool or sandpaper which might damage the surface sensor Do not use incompatible solvents which may damage the sensor s PP PFA PVDF or PPS plastic body 4 Sensor installation Follow the approp...

Страница 20: ...controller doesn t have an input indicator use a voltmeter or ammeter to ensure that the switch produces the correct signal see below 4 Point of actuation Observe the point at which the rising or fall...

Страница 21: ...21...

Страница 22: ...22...

Отзывы: