12
®
Technical Specifications
LVCN7000
2VA
5MHz
Level switch for liquids solids and granular
Cable gland - ½”NPT cond. entry or M12 connector
POM (Polyoxymethylene), PTFE or PVC
24 Vdc +/- 10%
Relay (SPDT) 5A max (250Vac)
Potentiometer - Switch Point
Potentiometer 1 to 20 seconds
Led status on/off
3/4” to 1 1/2” BSP or NPT flange or sanitary connections
Glass filled nylon
145 PSI (10 Bar)
14 to 176º F (-10 to 80ºC)
IP 65
Current Consumption
Frequency oscilation
Enclosure Material
Process Connection
Operating Temperature
Electrical Connection
Application
Operating Voltage
Output
Adjustment
Time Delay
Level indication
Wetted Material
Class Protection
Max pressure