Section 9 - Specifications

TEMPERATURE 
Measuring Range 

     Standard:

 

-30 to 75ºC (-22 ºF to 167ºF) without jumper on  

 

connector J4 

     Special: 

 -20 to 75°C (-4 to 167°F) with jumper added on 

connector J4 pin 1 to 2. See figure 3-2.

Accuracy: 

±0.6ºC from 0 to 50ºC (32 to 122ºF), 

 

±1.25ºC from - 30 to 0ºC (-22 to 32ºF) and 

 

50 to 75ºC (122 to 167ºF)

Repeatability:  

±0.2ºC (0.4ºF)

Resolution:  

0.1ºC

Response Time

5 Seconds min., 30 seconds max.

Sample Rate: 

1 Sample every 4 seconds

RELATIVE HUMIDITY
Measuring Range:

 

0 to 100%

Accuracy Range: 

 ±2.5 % from 20 to 80% RH, ±3.5% from 5 to 20% 

and 80 to 95% RH, ±4% from 0 to 5% and 95 to 

100% RH

Hysteresis:

  

±1%

Repeatability:  

±0.1%

Resolution:  

0.1%

Response Time: 

8 Seconds typical

Sample Rate

1 Sample every 4 seconds

Operating Temperature Range:  -30 to 75ºC
Input Power: 

9 to 30 Vdc @ 100mA:  

 

     4 to 20mA, 0-1 volt, 0-5 volt output 

 

12 to 30 Vdc @ 100mA: 

 

     0 to 10 volts output

Max Loop Resistance: 

200 Ohms @ 9 Vdc supply voltage 

(4 to 20 mA Output) 

1,250 Ohms @ 30 Vdc supply 

 

voltage Ohms = [(V supply - 4V) /0.02A)] -50

Max. Load Resistance:  

1.25 K (For all outputs: 0-1 Vdc, 0-5 Vdc, 

(min. resistance) 

0-10 Vdc)

Sensor Type:

 

Digital Sensor

Enclosure Housing: 

Gray Polycarbonate,  

 

NEMA 13 (IP54)

9-1

Specifications

9

Содержание HX93B Series

Страница 1: ...tters HX93B HX93BD WALL MOUNT HX93BD D DUCT MOUNT EASY M12 CONNECTION TH RP remote probe with 3 m 10 cable and M12 connector TM User sGuide Shop online at omega com e mail info omega com For the lates...

Страница 2: ...y U S and International Patents and Patents Pending omega com info omega com Omega Engineering Inc 800 Connecticut Ave Suite 5N01 Norwalk CT 06854 USA Toll Free 1 800 826 6342 USA Canada only Customer...

Страница 3: ...Measuring Range Selection 3 1 3 1 Electrical Connection 3 1 3 2 Temperature Measuring Range Selection 3 1 4 Mounting 4 1 5 Temperature Output Calculations 5 1 6 Relative Humidity Output Calculations...

Страница 4: ...itter Internal Diagram 1 1 Figure 3 1 Electrical Connection Diagram 3 1 Figure 3 2 Temperature Measuring Range Selection Diagram 3 1 Figure 4 1 Wall Mount Model Dimensions 4 1 Figure 4 2 Duct Mount Mo...

Страница 5: ...ith backlit to display both Temperature and Relative Humidity readings An on board slide switch allows the user to change the temperature reading from C to F as shown in figure 1 1 below Figure 1 1 Tr...

Страница 6: ...he container and equipment for any signs of damage Note any evidence of rough handling in transit Immediately report any damage to the shipping agent The carrier will not honor any damage claims unles...

Страница 7: ...ital Display Remote Probe Temperature Relative Humidity Transmitter 0 to 10 volt output with 3 m 10 cable HX93BC Wall Mount Temperature Relative Humidity Transmitter 4 to 20mA HX93BV0 Wall Mount Tempe...

Страница 8: ...J4 The standard temperature measuring range is 30 to 75 C 22 to 167 F without adding any jumper on connector J4 If you would like to change the range to 20 to 75 C 4 to 167 F add a jumper on connecto...

Страница 9: ...d for wall mounting and remote probe models A duct mounting kit is included with duct mount models See figure 4 1 figure 4 2 and figure 4 3 for the wall mount duct mount and remote probe model dimensi...

Страница 10: ...obe Model Dimensions Mounting 4 4 2 82 3 3 24 48 3 1 90 27 9 1 1 17 3 0 68 FLEXIBLE CABLE 2 9 m 9 5 54 1 2 13 254 10 127 3 5 01 80 0 3 15 DIMENSIONS mm in 43 8 24 2 C RH 55 6 2 19 128 0 5 04 15 7 0 63...

Страница 11: ...A 22 Offset temperature in F 0 0847 is the sensitivity which derived from the following Full scale current limit total temperature range 16 mA 189 F 0 0847mA F c To calculate temperature in C from a 0...

Страница 12: ...owing Total out put voltage range out temperature range 5 0 v 189 F 0 0265 V F g To calculate temperature in C from a 0 to 10 volt output for the temperature range of 30 to 75 C Formula Temperature in...

Страница 13: ...urrent measured in milliamps 4 0 16 Where 4 offset current in mA 0 16 Full scale current limit in percent For voltage output Formula RH voltage measured in volts x 100 a 1 volt output RH voltage measu...

Страница 14: ...transmitter has been digitally calibrated and tested to meet or exceed the specifications outlined in this manual in our factory The transmitter must be sent back to the factory for any re calibration...

Страница 15: ...filter if clogged may be removed for cleaning Unscrew the protective cover and gently blow compressed air through the filter screen A soft brush may also be used to remove dirt particles from the scr...

Страница 16: ...100 Accuracy Range 2 5 from 20 to 80 RH 3 5 from 5 to 20 and 80 to 95 RH 4 from 0 to 5 and 95 to 100 RH Hysteresis 1 Repeatability 0 1 Resolution 0 1 Response Time 8 Seconds typical Sample Rate 1 Sam...

Страница 17: ...pts 14 to 22 gauge wire Dimensions See Mounting Section Weight HX93B 151 g 8 9 oz HX93B D 256 g 9 0 oz HX93B RP1 352 g 12 4 oz Display HX93BD Series only Indicator Two 4 digit digital back lit LCD Dis...

Страница 18: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Страница 19: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Отзывы: