manualshive.com logo in svg
background image

HHWT-11

Handheld Chlorine Photometer

  e-mail: [email protected]

For latest product manuals:

www.omegamanual.info

Shop online at

omega.com

SM

User’s Guide

Содержание HHWT-11

Страница 1: ...HHWT 11 Handheld Chlorine Photometer e mail info omega com For latest product manuals www omegamanual info Shop online at omega comSM User sGuide...

Страница 2: ...pecifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Страница 3: ...HP6 pH 11 PH7 High Range Chlorine HRC 11 HR8 6SHFL FDWLRQV About Your Photometer 5 Tips for Best Accuracy 12 About the Built In Cell 12 Meter Messages 13 Battery Installation 13 Reorder Information 13...

Страница 4: ...GHG Battery Life WHVWV ZLWK DONDOLQH EDWWHULHV Electromagnetic Compliance PLWWHG QWHUIHUHQFH 1 EMC PPXQLW WR QWHUIHUHQFH 1 Waterproof Rating FHHGV 3 Weight QVWUXPHQW J R Dimensions QVWUXPHQW FP LQ HHW...

Страница 5: ...O SDUDPHWHUV AWWA 4500 Cl G Strip DPD 1 Anhydrous DPD sulfate Anhydrous Na2HPO4 Anhydrous KH2PO4Na2 EDTA 1 5 33 4 64 0 1 1 1 5 33 4 64 0 1 1 Component Free Chlorine About The Accuracy Calibration Of T...

Страница 6: ...20 SECOND countdown timer During this time move the strip in a gentle back and forth motion approx 2 strokes Sec Remove and discard the strip after 1 on the display disappears DIP STRIP AND PRESS READ...

Страница 7: ...oxide CL1 Chlorine and Iodine react with N N diethyl p phenylenediamine as it is released from the strip to form a magenta color directly proportional to the Chlorine concentration Ozone Bromine and P...

Страница 8: ...he 20 SECOND countdown timer During this time move the strip in a gentle back and forth motion approx 2 strokes sec Remove and discard the strip after 1 on the display disappears The cursor will move...

Страница 9: ...ON 1 Remove one 1 HHWT 486633 strip and one 1 HHWT 484014 strip from their bottles before beginning the test Set the strips in a dry convenient place and recap the bottles immediately REMOVE STRIPS C...

Страница 10: ...SUHYLRXV WHVW LQDOO OO FHOO WR FDSDFLW P ZLWK the water sample FILL METER WITH SAMPLE HP HP6 PA PA5 6 Dip the HHWT 486675 strip into the CELL and immediately press READ This starts the 20 SECOND coun...

Страница 11: ...ry convenient place and recap the bottle immediately REMOVE STRIP pH Test Procedure PH PH7 NOTE When testing outdoors sunlight for best accuracy use the Mixing Cap Cell Cover when Zeroing and Reading...

Страница 12: ...EO VPDOOHU RU ODUJHU LQ width than the normal strips in the bottle These should be discarded Using these strips may give incorrect results The HHWT 11 Photometer is not compatible for use with DPD 1 D...

Страница 13: ...igh quality AAA alkaline batteries be used 4 Replace the battery cover Be sure to tighten the cover securely Do not over tighten This is necessary for meter to be waterproof 5 Dispose of the used batt...

Страница 14: ...00 5 00 6 00 0 00 1 00 2 00 3 00 4 00 5 00 6 00 Hach DR890 ppm HHWT 11 ppm mg L ppm mg L DR890 HHWT 11 0 00 0 00 0 41 0 39 0 92 0 96 0 79 0 73 1 28 1 32 2 70 2 73 3 20 3 22 4 45 4 75 5 30 5 53 Meter M...

Страница 15: ...otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Страница 16: ...ity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...