5
FREQUENCY (Autoranging)
Ranges
5.000Hz,50.00Hz,500.0Hz,5.000KHz
Resolution
0.001Hz
Accuracy
±(0.05%rdg + 2dgts)
Sensitivity
1.0V rms min
Alternating Pulse or SINE wave signal on all range
Overload protection
500VDC or AC rms
DUTY CYCLE (2Hz to 1kHz)
Ranges
10% to 90%
Resolution
0.1%
Accuracy
±5dgts @ 2Vrms min Alternating Pulse signal
Pulse Width
50µs
Overload protection
500VDC or AC rms
TEMPERATURE (Autoranging)
Ranges
-4°F to 2498°F
Resolution
0.1°F or 1°F
Accuracy
±(2.0%rdg + 6°F) on -4°F to 923°F
±(3.0%rdg + 4°F) on 923°F to 2498°F
Содержание HHM60 Series
Страница 1: ...OMEGA HHM63F Digital Multimeter...