4
CONTINUITY
Audible indication: less than 30
W
on 2K
W
range
Overload protection: 600VDC or AC rms
DIODE TEST
Test current: 1.0mA±0.6mA
Accuracy: ±(6.0%rdg + 3dgts)
Open circuit volts: 3.0Vdc typical
Audible indication: <30mV
Overload protection: 600VDC or AC rms
AC CURRENT (Put conductor at the center of the jaws)
Ranges: 20A,200A,700A
Accuracy: 50-60Hz ±(1.5%rdg + 4dgts)
40-500Hz ±(3.5%rdg + 5dgts)
*700A to 1000A(50Hz-60Hz): ±(2.0%rdg + 4dgts)
Overload protection: 1000Aac max. for 1 minute
Содержание HHM598
Страница 1: ...OMEGA HHM598 Digital Clamp On Meter...