OMEGAnet
®
On-Line Service
Internet e-mail
omega.com
Czech Republic:
Frystatska 184, 733 01 Karvina´, Czech Republic
Tel: +420 (0)59 6311899
FAX: +420 (0)59 6311114
Toll Free: 0800-1-66342
e-mail: [email protected]
Germany/Austria:
Daimlerstrasse 26, D-75392
Deckenpfronn, Germany
Tel: +49 (0)7056 9398-0
FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678
e-mail: [email protected]
Servicing Europe:
U.S.A. and Canada:
Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
U.S.A.:
ISO 9001 Certified
One Omega Drive, Box 4047
Stamford, CT 06907-0047
Tel: (203) 359-1660
FAX: (203) 359-7700
e-mail: [email protected]
Servicing North America:
For immediate technical or application assistance:
Mexico:
En Espan
~ol: (001) 203-359-7803
FAX: (001) 203-359-7807
e-mail: [email protected]
United Kingdom
ISO 9002 Certified
One Omega Drive
River Bend Technology Centre
Northbank, Irlam
Manchester M44 5BD
United Kingdom
Tel: +44 (0)161 777 6611
FAX: +44 (0)161 777 6622
Toll Free in United Kingdom:
0800-488-488
e-mail: [email protected]
Canada:
976 Bergar
Laval (Quebec) H7L 5A1, Canada
Tel: (514) 856-6928
FAX: (514) 856-6886
e-mail: [email protected]
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
M4501/0607
TEMPERATURE
䡺
⻬
Thermocouple, RTD & Thermistor
Probes, Connectors, Panels &
Assemblies
䡺
⻬
Wire: Thermocouple, RTD &
Thermistor
䡺
⻬
Calibrators & Ice Point References
䡺
⻬
Recorders, Controllers & Process
Monitors
䡺
⻬
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
䡺
⻬
Transducers & Strain Gages
䡺
⻬
Load Cells & Pressure Gages
䡺
⻬
Displacement Transducers
䡺
⻬
Instrumentation & Accessories
FLOW/LEVEL
䡺
⻬
Rotameters, Gas Mass Flowmeters &
Flow Computers
䡺
⻬
Air Velocity Indicators
䡺
⻬
Turbine/Paddlewheel Systems
䡺
⻬
Totalizers & Batch Controllers
pH/CONDUCTIVITY
䡺
⻬
pH Electrodes, Testers & Accessories
䡺
⻬
Benchtop/Laboratory Meters
䡺
⻬
Controllers, Calibrators, Simulators &
Pumps
䡺
⻬
Industrial pH & Conductivity
Equipment
DATA ACQUISITION
䡺
⻬
Data Acquisition & Engineering
Software
䡺
⻬
Communications-Based Acquisition
Systems
䡺
⻬
Plug-in Cards for Apple, IBM &
Compatibles
䡺
⻬
Datalogging Systems
䡺
⻬
Recorders, Printers & Plotters
HEATERS
䡺
⻬
Heating Cable
䡺
⻬
Cartridge & Strip Heaters
䡺
⻬
Immersion & Band Heaters
䡺
⻬
Flexible Heaters
䡺
⻬
Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
䡺
⻬
Metering & Control Instrumentation
䡺
⻬
Refractometers
䡺
⻬
Pumps & Tubing
䡺
⻬
Air, Soil & Water Monitors
䡺
⻬
Industrial Water & Wastewater
Treatment
䡺
⻬
pH, Conductivity & Dissolved Oxygen
Instruments
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN
AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT
(IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be
marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to
prevent breakage in transit.
FOR
WARRANTY
RETURNS, please have
the following information available BEFORE
contacting OMEGA:
1. Purchase Order number under which
the product was PURCHASED,
2. Model and serial number of the product
under warranty, and
3. Repair instructions and/or specific
problems relative to the product.
FOR
NON-WARRANTY
REPAIRS, consult
OMEGA for current repair charges. Have the
following information available BEFORE
contacting OMEGA:
1. Purchase Order number to cover the
COST of the repair,
2. Model and serial number of the
product, and
3. Repair instructions and/or specific problems
relative to the product.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and
workmanship for a period of
13 months
from date of purchase. OMEGA’s WARRANTY adds
an additional one (1) month grace period to the normal
one (1) year product warranty
to
cover handling and shipping time. This ensures that OMEGA’s customers receive maximum
coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer
Service Department will issue an Authorized Return (AR) number immediately upon phone
or written request. Upon examination by OMEGA, if the unit is found to be defective, it will
be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects
resulting from any action of the purchaser, including but not limited to mishandling,
improper interfacing, operation outside of design limits, improper repair, or unauthorized
modification. This WARRANTY is VOID if the unit shows evidence of having been tampered
with or shows evidence of having been damaged as a result of excessive corrosion; or
current, heat, moisture or vibration; improper specification; misapplication; misuse or other
operating conditions outside of OMEGA’s control. Components in which wear is not
warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products.
However, OMEGA neither assumes responsibility for any omissions or errors nor
assumes liability for any damages that result from the use of its products in
accordance with information provided by OMEGA, either verbal or written.
OMEGA warrants only that the parts manufactured by the company will be as
specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED,
EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY
WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser
set forth herein are exclusive, and the total liability of OMEGA with respect to this
order, whether based on contract, warranty, negligence, indemnification, strict
liability or otherwise, shall not exceed the purchase price of the component upon
which liability is based. In no event shall OMEGA be liable for consequential,
incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1)
as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or
activity; or (2) in medical applications or used on humans. Should any Product(s) be used in
or with any nuclear installation or activity, medical application, used on humans, or misused
in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY /
DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold
OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
he policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI
ations that apply. OMEGA is constantly pursuing certification of its products to the
pean New Approach Directives. OMEGA will add the CE mark to every appropriate device
certification.
nformation contained in this document is believed to be correct, but OMEGA accepts no
ty for any errors it contains, and reserves the right to alter specifications without notice.
NING:
These products are not designed for use in, and should not be used for, human
cations.
OMEGAʼs policy is to make running changes, not model changes, whenever an improvement is
possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2007 OMEGA ENGINEERING, INC. All rights reserved. This document may not be
copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-
readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
overlay ENTER key, stored the relative value, enter Time set mode.
Time set mode, (Press ENTER key can escape Time set mode) =.= = = : =
= is displayed in second and third display. Time (hours, minutes, seconds)
value is entered via overlay numbers, then press overlay ENTER key.
Time start from set time value, enter Hi/Lo Limits value set mode.
Hi Limit value set mode, (Press ENTER key can escape Hi Limit value set
mode), = = = =.= is displayed in main display, Hi Limit value is entered
via overlay numbers, then press overlay ENTER key, stored the Hi Limit
value, enter Lo Limit value set mode (Press ENTER key can escape Lo
Limit value set mode). = = = =.= is displayed in main display, Lo Limit
value is entered via overlay numbers, then press overlay ENTER key,
stored the Lo Limit value and exit SET mode.
When the thermometer is turned on. The Relative set value and Hi/Lo
Limits set value that was in use when thermometer was last turned off set
values.
T1/T2 T1-T2 second display Input Selection
he input selection button determines which input is shown on the second
splay; T1 ,T2 or the difference between the two probes (T1-T2). When the
ermometer is turned on, it is set to T2.
TYPE(Pt385/Pt3926/Pt3916) Input RTD Probe select (second display)
he TYPE button selects the RTD curve to use for the input currently
own. When the thermometer is turned on, it is set to the curve that was
lected when the thermometer was last turned off.
Hi/Lo Limits mode (only Main display)
ess the Hi/Lo Limits button to enter the Hi/Lo Limits comparative mode,
hen the input temperature exceeds the Hi or Lo Limits value, the beeper
mits a continuous pulse tone. Press the Hi/Lo Limits button again to exit
e Hi/Lo Limits mode.
TD PROBE CONNECTION
MPERATURE VS RESISTANCE TABLE(ITS90)
°C
Pt385
Pt3926
Pt3916
-200°C
18.521_
16.996_
17.057_
-100°C
60.256_
59.479_
59.565_
0°C
100.000_
100.000_
100.000_
100°C
138.505_
139.272_
139.171_
200°C
175.856_
177.362_
177.155_
300°C
212.052_
214.275_
213.957_
400°C
247.092_
250.018_
249.584_
500°C
280.977_
284.591_
284.036_
600°C
313.708_
317.994_
317.313_
700°C
345.280_
-
-
800°C
375.700_
-
-
OPERATOR MAINTENANCE
WARNING
To avoid possible electrical shock, disconnect the thermocouple connectors
from the thermometer before removing the cover.
Battery Replacement
1. Power is supplied by 4pcs 1.5V (SIZE AAA) R03P.
2. The “
” appears on the LCD display when replacement is needed. To
replace battery remove screw from back of meter and lift off the battery cover.
3. Remove the battery from battery contacts and replace.
4. When not in use for long periods the batteries should be removed.
5. Do not store in locations with high temperatures, or high humidity.
Cleaning
Periodically wipe the case with a damp cloth and detergent, do not use abra
sives or solvents.
V1. 040307