background image

Reed Relay Specifications

Two wire SPST N/O.

Switching voltage 150 VDC; maximum
current 0.25 Amps.

Rating 3 watts.

Duty cycle 20% ON, 80% OFF.

Disassembly:

1. Ensure the fluid supply to the meter has

been disconnected, and the line pres-
sure has been released before disas-
sembly.

2. Remove the four screws and remove the

pulser cap.

3. Remove the gasket.

4. Remove eight screws and remove the

meter cap.

5. Remove O-ring and inspect. Replace O-

ring if damaged.

6. Remove rotors, clean and inspect. Re-

place rotors if damaged.

7. To  remove the PCB, remove the two

screws.

NOTE:  Reed Switch PCB’s cannot be re-

moved.

2

Reassembly:

1. Replace rotors into the meter body. The

rotors should be at 90 degrees to each
other.

2. Lightly rotate the rotors by hand. They

must rotate freely.

3. Install O-ring.

4. Replace the meter cap and tighten the

eight screws uniformly to 35Nm (25 Ft.
Lbs.).

5. Replace the pulser cap and tighten the

four screws.

MAINTENANCE

Figure 3

12

Reed Switch Wiring Details

(HP Models Only)

Содержание FPD1000-HP Series

Страница 1: ...FPD1000 HP SERIES HIGH PRESSURE Positive Displacement Flowmeters...

Страница 2: ......

Страница 3: ...are suit able for both gravity and pump in line ap plications Please read this information carefully before use Before use confirm the fluid to be used is compatible with the meter or consult with OM...

Страница 4: ...ap 5 Remove O ring and inspect Replace O ring if damaged 6 Remove rotors clean and inspect Re place rotors if damaged 7 To remove the PCB remove the two screws NOTE Reed Switch PCB s cannot be re move...

Страница 5: ...trainer partially Clean strainer THROUGH THE blocked METER 2 Fluid is too viscous Maximum viscosity 1000 centipoise METER READING 1 Fluid flowrate is too low See specifications for minimum and INACCUR...

Страница 6: ...ap NPT 4 4 u MS115S Bolt Set Socket Head 6 1 MS3HES Meter Cap Hall Effect Assembly 6 1 MS3HPS Meter Cap Reed Switch Assembly 7 2 u MS6 1S Rotor Set Stainless Steel 8 1 u BS029V O Ring Viton 8 1 u BS02...

Страница 7: ...to 26 4 Accuracy of Reading 1 Maximum Viscosity 1000 Centipoise Maximum Operating Pressure 55160 kPa 8000 PSI 551 Bar Maximum Operating Temperature 120 C 248 F Pulse Type Hall Effect Sensor Reed Swit...

Страница 8: ...ly 6 1 MS3HPS Meter Cap Reed Switch Assembly 7 2 u MS7 1ES Rotor Set S Steel Hall Effect 7 2 u MS7 1RS Rotor Set S Steel Reed Switch 7 2 u MS7 1HES Rotor Set S Steel Hall Effect High Visc 7 2 u MS7 1H...

Страница 9: ...Reading 1 Maximum Viscosity 1000 Centipoise Maximum Operating Pressure 55160 kPa 8000 PSI 551 Bar Maximum Operating Temperature 120 C 248 F Pulse Type Hall Effect Sensor Reed Switch Pulses per Litre...

Страница 10: ......

Страница 11: ......

Страница 12: ...M 4125 0405...

Отзывы: