Introduction/Safety

Your FP7002/FP7002A has been designed for ease of use and flexibility. 

It is important that you read this user’s manual completely and follow 

all safety precautions before operating your unit.
Precautions

1.  FOLLOW ALL SAFETY PRECAUTIONS AND OPERATING 

INSTRUCTIONS OUTLINED IN THIS MANUAL.

3.  ADD ADDITIONAL SAFEGUARDS TO YOUR SYSTEM IN 

CRITICAL APPLICATIONS WHERE DAMAGE OR INJURY 

MAY RESULT FROM SENSOR FAILURE.

5.  DO NOT OPERATE IN FLAMMABLE OR EXPLOSIVE 

ENVIRONMENTS.

6.  DO NOT USE IN HUMAN MEDICAL OR NUCLEAR 

APPLICATIONS.

7.  NEVER OPERATE WITH A POWER SOURCE OTHER THAN 

WHAT IS SPECIFIED IN THIS MANUAL.

8.   REMOVE AND/OR DISCONNECT POWER SOURCE BEFORE 

ATTEMPTING INSTALLATION OR MAINTENANCE.

9.  ALWAYS OPERATE YOUR UNIT WITH THE SHIELD WIRE 

CONNECTED TO EARTH GROUND.

10.  INSTALLATION AND WIRING SHOULD BE DONE BY 

TRAINED PROFESSIONALS ONLY.

N O T E

There are no user serviceable parts inside your unit. 

Attempting to open, repair or service your unit may void 

your warranty.

FP7002/FP7002A Flow/Temperature Transmitter

ii

Содержание FP7002

Страница 1: ...FP7002 FP7002A Flow Temperature Transmitter TM e mail info omega com For latest product manuals www omegamanual info Shop online at omega com User sGuide NORWALK CT...

Страница 2: ...rves the right to alter specifications without notice Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Страница 3: ...1 2 2 Important Considerations Before Installation 1 2 3 Flowmeter Installation 2 2 4 Electrical Connections 4 Section 3 Maintenance 5 Section 4 Calibration 5 4 1 Flow Calibration 5 4 2 Temperature C...

Страница 4: ...SENSOR FAILURE 5 DO NOT OPERATE IN FLAMMABLE OR EXPLOSIVE ENVIRONMENTS 6 DO NOT USE IN HUMAN MEDICAL OR NUCLEAR APPLICATIONS 7 NEVER OPERATE WITH A POWER SOURCE OTHER THAN WHAT IS SPECIFIED IN THIS M...

Страница 5: ...fittings are supplied with a brass locking nut to provide a secure metal to metal mounting to the threaded brass insert Section 2 Installation 2 1 Unpacking Remove the Packing List and verify that you...

Страница 6: ...PPED AS WITH QUICK CLOSING AND SOLENOID OPERATED VALVES SURGES OCCUR WHEN FLOW IS SUDDENLY BEGUN AS WHEN A PUMP IS TURNED ON AT FULL POWER OR A VALVE IS QUICKLY OPENED LIQUID SURGES ARE PARTICULARLY D...

Страница 7: ...FP7002 FP7002A Flow Temperature Transmitter 2 3 FLOW Figure 2 1 Horizontal Mounting Position FLOW Figure 2 2 Vertical Mounting Position...

Страница 8: ...of the downstream obstruction Table 2 1 Concentric reducer 15 pipe diameters One elbow 20 pipe diameters 2 elbows in same plane 25 pipe diameters 2 elbows in two planes 40 pipe diameters or one expan...

Страница 9: ...am from the FP7002 and to periodically shut down the line and remove the sensor from the installation fitting for cleaning 2 4 Electrical Connections CAUTION All electrical connections and wiring shou...

Страница 10: ...on For our example we will use GPM This will be GPM Max 5 From the table on page 8 determine the proper K Factor for the model fitting you will be using 6 Determine your full scale calibration frequen...

Страница 11: ...s 4 Place a reference temperature probe next to the body of the paddlewheel flow sensor with the unit removed from the flow line and lying on a work bench 5 Connect the reference probe to a thermomete...

Страница 12: ...etup Figure 4 2 Temperature Calibration Setup 1 2 3 4 5 6 1 5 4 3 2 6 P2 P1 REMOVE RESISTOR AND WHITE WIRE FOR CALIBRATION TB3 TB6 TB1 TB4 4 00 mA 0 00 Hz MULTIMETER FREQUENCY GENERATOR 18 Vdc MAX PWR...

Страница 13: ...FP7012 41 16 FP7012 GI 48 81 FP7015 29 46 FP7015 GI 35 52 FP7020 15 52 FP7020 GI 20 62 FP7025 11 40 FP7025 GI 12 44 FP7030 6 64 FP7030 GI 7 22 PART NUMBER K FACTOR ART NUMBER K FACTOR VISCOSITY and S...

Страница 14: ...ERIALS Sensor Body Polypropylene body PVDF optional PVDF paddle Viton O ring 316SS shaft Model FP7002A includes brass locking nut Model FP7002 includes PVC locking nut MAX RECOMMENDED FLUID VISCOSITY...

Страница 15: ...or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment...

Страница 16: ...ne Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industrial...