OMEGA DPU91-BC Batch Controller System
Contrast
Adjust the LCD contrast for best viewing. A setting of 1 is lowest
contrast, 5 is highest. In general, select lower contrast if the display is in warmer
surroundings. Default = 3.
Backlight
Adjust backlight level. Select OFF, LOW, HIGH or AUTO.
Default = AUTO.
Batch Decimal
Set the decimal to the best resolution for your application. The
display will automatically scale up to this resolution. Select -----., ----.-, ---.-- or
--.---. Default = ----.-.
Total Decimal
Set the decimal to the best resolution for the Permanent Totalizer
display. The display will automatically scale up to this resolution. Select -----.,
----.-, ---.-- or --.---. Default = ----.-.
PWD REQUIRED
requires password to reset TOTALIZER, BATCH OVERRIDE,
SOURCE VOLUME reset, and BATCH COUNT reset. Select YES/NO.
(Does not affect Permanent Totalizer.) Default = YES.
Source Volume
Selects SOURCE VOLUME display option. Choose ON or OFF.
Default = OFF.
Volume Reset
If SOURCE VOLUME is ON, set the reset value for the source
volume. Default = 1000 GAL.
Bar Graph Source
If SOURCE VOLUME is ON, select source for Bar Graph
(choose BATCH VOLUME or SOURCE VOLUME). If SOURCE VOLUME is
OFF, Bar Graph source is the batch volume. Default = BATCH VOLUME.
Password Type
Select STD or CODE. Default = STD.
Set Code
If CODE is selected in PASSWORD TYPE, enter desired password
code. 4-character entry not displayed, ---- displayed instead.
Memo
Enter 13-character string, if desired.
Remote Setup
Enables Remote Setup to con
fi
gure the DPU91 via a computer
and the PC COMM tool. Press
►
and select YES to enable. REMOTE SETUP
flashes when mode is enabled.
Refer to the PC COMM Configuration/Diagnostic Tool manual, DPU90-CT,
included with your PC COMM tool.
Version Level
Generation II or later indicates that the DPU91 is Batch-capable.
OPTION Menu