manualshive.com logo in svg
background image

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords 

our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2017 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, 

reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the 

prior written consent of OMEGA ENGINEERING, INC.

FOR 

WARRANTY

 RETURNS, please have the  

following information available BEFORE contacting 

OMEGA:
1.   Purchase Order number under which the product 

was PURCHASED,

2.   Model and serial number of the product under 

warranty, and

3.  Repair instructions and/or specific problems  

  relative to the product.

FOR 

NON-WARRANTY

 REPAIRS, consult 

OMEGA for current repair charges. Have 

the following information available BEFORE 

contacting OMEGA:
1.  Purchase Order number to cover the COST  

  of the repair,
2.  Model and serial number of the product, and
3.  Repair instructions and/or specific problems  

  relative to the product.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. 

BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED 

RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID 

PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return 

package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent 

breakage in transit. 

 

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a 

period of 

13 months

 from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month 

grace period to the normal 

one (1) year product warranty

 to cover handling and shipping time. This 

ensures that OMEGA’s customers receive maximum coverage on each product. 
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service 

Department will issue an Authorized Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no 

charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, 

including but not limited to mishandling, improper interfacing, operation outside of design limits,  

improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  

having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; 

or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating 

conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not  

limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However,  

OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for 

any damages that result from the use of its products in accordance with information provided 

by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR  

REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF 

TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF  

LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of  

OMEGA with respect to this order, whether based on contract, warranty, negligence,  

indemnification, strict liability or otherwise, shall not exceed the purchase price of the  

component upon which liability is based. In no event shall OMEGA be liable for  

consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic 

Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical 

applications or used on humans. Should any Product(s) be used in or with any nuclear installation or 

activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility 

as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify 

OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the 

Product(s) in such a manner.

Содержание DMD4059

Страница 1: ...ncrements Maximum Output 10 VDC maximum at 120 mA Drive Capability Up to four 350 Ω bridges at 10 VDC Fine Adjustment 5 via multi turn potentiometer Stability 0 01 per C Sense Lead Compensation Better than 0 01 per 1 Ω change in leadwire resistance Maximum leadwire resistance 10 Ω with 350 Ω at 10 VDC LoopTracker Variable brightness LEDs for input output loop level and status DC Output Ranges Volt...

Страница 2: ...000V 008V 001V 006V 009V 002V 007V 003V 004V 005V 000I 008I 001I 006I 009I 002I 007I 003I 0 100 mV 800V 808V 801V 806V 809V 802V 807V 803V 804V 805V 800I 808I 801I 806I 809I 802I 807I 803I 0 120 mV F00V F08V F01V F06V F09V F02V F07V F03V F04V F05V F00I F08I F01I F06I F09I F02I F07I F03I 0 200 mV 100V 108V 101V 106V 109V 102V 107V 103V 104V 105V 100I 108I 101I 106I 109I 102I 107I 103I 0 250 mV 400V...

Страница 3: ...tputs failure to illuminate or a failure to change in intensity as the process changes may indicate a problem with the module power or signal output wiring Diagnostic Voltage Measurements Using a meter with at least 10 megaohm input impedance measure the voltage coming from the strain gauge at the locations shown Sensitivity is measured in mV V Positive Meter Lead Negative Meter Lead Meter Reading...

Страница 4: ...by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or ...

Отзывы: