Omega 1376 Скачать руководство пользователя страница 7

Fig. 1.0

1.0 Electrical tests

Rate adjustment by inhibition. The rate can only be 

measured using an instrument capable of measuring for 

sixty seconds or multiple times sixty seconds.

1.1 Fitting the battery

Slide the battery under the battery clamp no. 4400. Gently 

press on battery to position it in place with the  

no. 4401.

Speci

fi

 c information for calibre 1376 

Pos. Setting of apparatus Measurement

Test

Remarks

1

2 V

(Ri 

 10 k

Ω

 / V)

1,55 V

Battery voltage

2

1 V

(Ri 

 10 k

Ω

 / V)

For the Witschi Q 6000:

The «Motor» LED lights up with

every impulse.

Impulses per minute at 

the integrated circuit 

output 3 per minute

Measured with checked battery.

3

10 

μ

A

 0,70 

μ

A

Movement consumption

Measured without battery, 

external supply, 1.55 V. 

2 V

 1,30 V

Lower limit for 

operating voltage

Measured without battery, 

variable external supply,  starting 

with 1.55V, continually reduce 

voltage until movement stops

4

• 10 k

Ω

1,55 V ~ 1,85 k

Ω

Condition of coil 

5

• 100 k

Ω

- Coil 

insulation

6

Remark: With the additional contact position 6, R/T with the – contact, the motor is driven with 16 or 32 steps/s

The clockwise rotation of the hands allows an immediate check. 

Ohmmeters with measuring voltage greater than 0.40V inappropriate; recommended voltage 0.20V.
Ambient  temperature 20°C.

#

3

5

4

1

2

6

OMEGA 

1376 

OMEGA 

1376 

#

4400 

4401 

OMEGA 

1376 

#

OMEGA SA  

WORLD SERVICE ORGANIZATION  

GT-19-C-047-E - C - 1376

/7

Содержание 1376

Страница 1: ...o Yes Omega personalised quartz movement featuring circular graining rhodium plating and gilded engraving Hour hand and minute hand Rate adjustment by inhibition Stepper motor with three impulses per...

Страница 2: ...sion 4 Spare parts list for calibre 1376 5 Calibre 1376 1 General information for calibre 1376 3 Tools Specific information for calibre 1376 6 Information on height of hands Runners for hand setting a...

Страница 3: ...1 UCAR Ray O Vac Energizer 321 Maxell Panasonic and Sony SR616SW Movement exchange is recommended According to Working Instruction 31 Repair and movement exchange policy Mandatory tools Hand fitting R...

Страница 4: ...AH3 1 3 7 6 HXB 13 76 HXB AH3 AH3 Rohs version calibre 1376B 1 3 7 6 AH3 13 76 AH2 H 2 1 3 7 6 AH2 H 2 Non RoHS version calibre 1376A Differences between a RoHS version and a non RoHS version OMEGA S...

Страница 5: ...ce 1376A 1449934 1376B Battery insulator Calibre Reference 1376A 72213764046 1376B Bridle Calibre Reference 1376A 72213764401 1376B Handsetting stem 0 80 mm L 18 75 mm Calibre Reference 1376A 72213749...

Страница 6: ...ion H2B OMEGA SA WORLD SERVICE ORGANIZATION GT 19 C 047 E C 1376 6 Specific information for calibre 1376 Designation Movement holder No of runners for hand setting Minimum force N Maximum force N Supp...

Страница 7: ...circuit output 3 per minute Measured with checked battery 3 10 A 0 70 A Movement consumption Measured without battery external supply 1 55 V 2 V 1 30 V Lower limit for operating voltage Measured with...

Страница 8: ...N Maximum force N Support jewel Hour hand 8 30 no Minute hand 8 30 no Page 6 Adds Runners for hand setting and hand setting force Movement holder for hand setting No of runners for hand setting 507 0...

Отзывы: