background image

1973

Cal. 1310

21

5.1 Measuring of the rate (Deltatest)

Press key (2) of keyboard " < 15' Hz" ["1 Hz ".]

Move the watch in order to secure maximum 
signal.

Regulate amplification (6) by observing the level 
control provided by the instrument hand (7). 
Optimal adjustment is secured when the hand is at 
the beginning of the black zone [green zone]

Select by means of (3) the measuring time of 12 
[10] seconds.

Select by means of (4) the measuring accuracy of 
.99 [1/100.]

6.1 Measuring of the power cell tension (Alitest)

With power cell placed on table, connect black 
probe to top of power cell (-) and red probe to its 
case (+).

The tension value must be in the region of 1.35V; 
if it is below 1.25V, the power cell must be 
replaced.

6.2 Measuring of the current (Alitest)

This measuring is effected by using substitute 
power cell feed (15) connected with "Output" by 
means of the feeding clip (13).

Press buttons (2) [1.35 V] relating to feed tension 
of the watch and (8) [

µ

A] enabling the current to 

be measured.

The value measured should not exceed 15 

µ

A.

6.3 Checking of the functioning limit tensions 
(Alitest)

This checking is effected by using substitute 
power cell feed (15) connected with "Output" by 
means of the feeding cable (13).

Press buttons (4) [Uadj] and (9) [Vadj].

Check proper functioning of movement within the 
tension limits of 1.15 V and 1.40 V (tensions are 
regulated by means of knob (5)).

Note

The motor is said to function normally when the 
second wheel makes one complete revolution in 
one minute. It is important to check the passage of 
each of the 60 teeth.

6.4 Analysis of motor - measuring of the coil 
resistance

Note:

If the movement is under tension, it is necessary to 
isolate the electronic module before measuring the 
resistance.

Unscrew the two motor connecting-screws.

Slide an insulating leaf under the terminals of the 
module (A and B).

Measure R by applying the probes (16) to the 
terminals A and B.

The resistance of the motor

should be between 2 and 2.2 K. If this is not the 
case, the motor module must be changed.

6.5 Measuring of the rate on Deltatest using 
feed from Alitest

Connect Alitest to "Input"
of Deltatest by means of the special cable.

Proceed in identical manner to 6.2 : Measuring of 
the current.

Press button Atten. Deltatest (12) [Switch on back 
of Alitest in position 1].

Содержание 1310

Страница 1: ...lacement of power cell IMPORTANT To be observed strictly The watch must in no case be demagnetized In order not to disturb the proper functioning of the watch the electronic module fig 1 1 must not be...

Страница 2: ...m If the contacts are oxidized it is necessary in the case of the power cell bridle positive pole to replace the bridle No 1310 9179 the lower power cell contact negative pole to clean carefully the b...

Страница 3: ...the rate Electronic module fig 1 2 IMPORTANT To be observed strictly The watch must in no case be demagnetized In order not to disturb the proper functioning of the watch the electronic module fig 1 2...

Страница 4: ...d will be used 2 4 Read instant rate shown on DELTATEST Note Adjustment can only be effected if the daily rate is lower than the possibilities offered by the trimmer The guide mark printed on the trim...

Страница 5: ...the watch in relation to the ambient temperature according to fig 4 2 In order that the temperature of the watch may be equal to the ambient temperature it is necessary to wait about one hour before...

Страница 6: ...uch the electronic module with the fingers nor unsolder the elements The motor module must IN NO CASE be disassembled the characteristics of the magnetic circuit would be disturbed Do not clean the el...

Страница 7: ...ng stem and place dial and hands in position turn hour and minute hands backwards in order to compensate the backlash before fitting the second hand This latter hand will be fitted on an even number i...

Страница 8: ...3 22 Place new electronic module in position Important For this operation the hand setting stem must be pushed in 3 23 Tighten the 5 screws according to op 3 20 and fig 1 3 3 24 Follow operations in t...

Страница 9: ...n is free without backlash Important Check rotation of wheel train curing one minute at least 3 38 The backlash between motor and second wheel is then obtained by turning the motor eccentric through a...

Страница 10: ...rding to fig 5 3 3 45 Start the watch by pushing hand setting stem Engage click in retaining wheel by turning the click stud until the blade touches the tooth c Turn slightly further the click stud in...

Страница 11: ...netized Do not touch the electronic module with the fingers nor unsolder the elements The motor module must IN NO CASE be disassembled the characteristics of the magnetic circuit would be disturbed Do...

Страница 12: ...1973 Cal 1310 12...

Страница 13: ...1973 Cal 1310 13...

Страница 14: ...1973 Cal 1310 14...

Страница 15: ...should be cleaned in the appropriate benzine bath which must be absolutely clean and free from any metallic particles Check however the cleanliness of the magnets 4 6 13 0 Minute wheel 1310 9020 Impo...

Страница 16: ...1973 Cal 1310 16...

Страница 17: ...1973 Cal 1310 17...

Страница 18: ...1973 Cal 1310 18...

Страница 19: ...1310 9057 turn slightly until the three fingers are visible one of the three magnetic teeth must then be located under the upper pinion of the day disc driving gear No 1310 9057 4 9 6 0 Fit the date...

Страница 20: ...t and Alitest Note The numbers in parentheses refer to the numbers appearing in the instructions for use of the Deltatest ODT 3 and Alitest OAT 2 apparatus Indications in brackets refer to the Deltate...

Страница 21: ...functioning limit tensions Alitest This checking is effected by using substitute power cell feed 15 connected with Output by means of the feeding cable 13 Press buttons 4 Uadj and 9 Vadj Check proper...

Страница 22: ...p requests by our General Agents we are presenting a refined check method to make servicing of caliber 1310 easier The contents of the technical guide folder 0 to 6 remain valid 1 CHECK DELTATEST Acce...

Страница 23: ...and second wheel see pt 9 c endshake and freedom of rotor d cleanliness of motor worm gear 6 FUNCTIONING LIMITS MOTOR MODULE WITHOUT WHEEL TRAIN Lower limit 1 15 V upper limit 1 45 V Beyond accepted l...

Страница 24: ...movement must be 1 4 to 1 2 of the distance between two teeth figure 2 Repeat this control twice after 20 seconds 120 9 3 If the backlash has to be modified turn the eccentric for motor in the direct...

Отзывы: