Omega Lift Equipment 18126A Скачать руководство пользователя страница 2

2

SAFETY AND GENERAL INFORMATION

Save these instructions. 

For your safety, read, understand, and follow the information provided with and on this 

device before using. The owner and/or operator shall have an understanding of the device, its operating characteristics 

and safety operating instructions before operating the equipment. The owner and/or operator shall be aware that use 

and repair of this product may require special skills and knowledge. Instructions and safety information shall be read 

to and discussed with the operator in the operator's native language, making sure that the operator comprehends 

their contents, before use of this equipment is authorized. If any doubt exists as to the safe and proper use of this 

device, remove from service immediately. 

Inspect before each use.

 Do not use if abnormal conditions such as cracked welds, damaged, loose or missing 

parts are noted. Any equipment that appears damaged in any way, is found to be worn, or operates abnormally shall 

be removed from service until repaired. If the equipment has been or is suspected to have been subjected to an 

abnormal load or shock, immediately discontinue use until inspected by a factory authorized repair facility (contact 

distributor or manufacturer for list of authorized repair facilities). It is recommended that an annual inspection be 

made by an authorized repair facility. Labels and Operator's Manuals are available from the manufacturer. 

PRODUCT DESCRIPTION

Omega Air Actuated Hydraulic Bottle Jack is designed to lift, not support, rated capacity loads consisting of one end 

of a vehicle. Immediately after lifting, the load must be supported by a pair of appropriately rated jack stands. Ensure 

that air source can dedicate 7.8 CFM @ 110-175 psi to each jack operated. A minimum of 150 psi air pressure is 

required to raise rated capacity load.

WARNING: Never use a hydraulic jack as a stand alone device. After lifting, immediately support the lifted 

load with a pair of appropriately rated jack stands.

PREPARATION

Before Use

1. Before using this product, read the operator's manual completely and familiarize yourself thoroughly with the 

product, its components and recognize the hazards associated with its use.

3. Assemble handle, ensure spring clips align with slots.

4. To familiarize yourself with basic operation, use the notched end of provided handle to engage and turn the 

release valve:

a. 

Clockwise

CLOSED

’ release valve position used to 

    raise the ram plunger.

b. 

Counter-clockwise

OPEN

’ release valve 

    position used to lower the ram plunger.

5. With saddle fully lowered, and release valve closed, pump the operating handle.  If lift arm responds immediately, 

jack is ready for use.  If jack does not respond, follow 

Bleeding/Venting Trapped Air 

procedure below. 

6. Pour a teaspoon of good quality, air tool lubricant into the air supply inlet of the lift control valve. Connect to air 

supply and squeeze lift control valve for 3 seconds to evenly distribute lubricant.

choice, ensure that thread tape or compound is used when servicing connections. To ensure dependable, trouble 

free operation an in-line air dryer and oiler is recommended.

8. Check that the pump operates smoothly and that the extension screw will thread up/down easily before putting 

into service. Replace worn or damaged parts and assemblies with Omega authorized replacement parts only.

Bleeding/Venting Trapped Air

With the release valve in the OPEN position (4b above) and with ram plunger fully lowered, locate and remove the 

!

2. Verify that the product and application are compatible, if in doubt call Omega Technical Service (03) 9755 8277.

Содержание 18126A

Страница 1: ...the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Model 18126A 18206A Working Load...

Страница 2: ...air source can dedicate 7 8 CFM 110 175 psi to each jack operated A minimum of 150 psi air pressure is required to raise rated capacity load WARNING Never use a hydraulic jack as a stand alone device...

Страница 3: ...load supported only by hydraulic jack Always use adequately rated jack stands Chock each unlifted tire in both directions Do not use this device to lift level lower support nor move a house mobile ho...

Страница 4: ...se valve and operate the Handle Sleeve If handle is worn operates abnormally or will not positively engage the release valve STOP discontinue use of the jack until a factory replacement handle can be...

Страница 5: ...aning Periodically check the pump piston and ram for signs of rust corrosion Clean as needed and wipe with oily cloth NOTICE Do not use sandpaper or abrasive material on ram and pump piston surfaces S...

Страница 6: ...rts give Model number serial number and parts description Call or write for current pricing SHINN FU AUSTRALIA PTY LTD 15 Viewtech Place Rowville 3178 VIC Australia E mail sales sfaa com au Phone 03 9...

Страница 7: ...0 000 Air Inlet Swivel 1 23 A120 01400 000 A120 01400 000 Quick coupler Male 1 24 A240 02300 000 A240 02300 000 Quick coupler Female 1 25 A120 01000 000 A120 01000 000 Hose Assy 1 26 A240 02100 000 A2...

Страница 8: ...arranty is void if the product has been tampered with or repaired by any unauthorised person or has been modified in any way 5 If a warranty service is required the purchaser should Take the product t...

Отзывы: