background image

Specifications

5

9

5.2 - Laser Sight Accessory

Laser Wavelength (Color):

630 - 670 nm (Red)

Operating Distance:

Up to 9.1 m (30 ft.)

Max. Laser Power Output:

Less than 1 mW @ 22ºC ambient

European Classification:

Class 2, EN60825-1/11.2001

FDA Classification:

Class II Laser Product. Complies with
21 CFR 1040.10

Laser Beam Diameter:

Less than 5 mm

Beam Divergence:

Less than 2 mrad

Operating Temperature:

0 to 50°C (32 to 122°F)

Operating Relative Humidity:

Less than 95% RH, non-condensing

Power Switch:

ON/OFF, Slide switch on the Battery Pack

Power Indicator:

Red LED

Power:

Battery Pack, 3 VDC

Caution & Certification Label:

Located on the head sight circumference

Identification Label:

Located on the head sight circumference

Aperture Label:

Located on the head sight circumference

Dimensions:

38 OD x 50.8 L mm (1.5" OD x 2" L)

Содержание OS136 SERIES

Страница 1: ...ost Non Contact Infrared Temperature Sensor Transmitter CAUTION This product is not intended for medical use or use on humans e mail info omega com For latest product manuals omegamanual info Shop onl...

Страница 2: ...Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free...

Страница 3: ...mbols iii Section 1 Introduction 1 Section 2 Installation 1 2 1 Unpacking 1 2 2 Electrical Connection 2 Section 3 Operation 3 3 1 Measuring Temperature 3 3 2 Ambient Temperature 3 3 3 Atmospheric Qual...

Страница 4: ...Description Page 2 1 General Wiring Diagram 2 3 1 Optical Field of View 3 3 2 Mounting Bracket OS100 MB 4 3 3 Air Purge Collar OS100 AP 4 3 4 Stainless Steel Housing 5 3 5 Water Air Cool Jacket OS136...

Страница 5: ...The cable is a multi conductor 24 AWG stranded wire with the rating of 600 VDC 205 C 401 F Teflon insulation Power must be disconnected before making any electrical connections The recommended power...

Страница 6: ...4 rated The unit comes with a 1 82 m 6 shielded cable as standard SECTION 2 INSTALLATION 2 1 Unpacking Remove the packing list and verify that you have received all your equipment If you have any que...

Страница 7: ...r and output connections Fig 2 1 shows the wiring diagram for different analog outputs Figure 2 1 General Wiring Diagram Accessories Model No Description OS100 MB Mounting Bracket OS136 WC Water Air C...

Страница 8: ...tter can operate in an ambient temperature of 0 to 70 C 32 to 158 F without any water cool jacket It can operate from 0 to 200 C 32 to 392 F with the water cool jacket accessory OS136 WC Fig 3 5 3 6 I...

Страница 9: ...e following figures show the Mounting Bracket OS136 MB Air Purge Collar OS136 AP Stainless Steel Housing Water Air Cool Jacket OS136 WC and the Water Air Cool Jacket Assembly Figure 3 2 Mounting Brack...

Страница 10: ...HEX KNURL 4 76 3 16 WIDE DIMENSIONS mm in 3 4 16 UNF 88 9 3 5 1 83m 6ft 33 27 1 31 19 05 0 75 1 8 NPT COMPRESSION FITTING 2 PLCS 34 80 1 37 85 09 3 35 7 62 0 30 3 4 16 UNF 2B 3 4 16 UNF INLET OUTLET D...

Страница 11: ...de 4 2 Operating the Laser Sight Accessory The Laser sight accessory screws onto the front of the transmitter sensor head This accessory is only used for alignment of the transmitter head to the targe...

Страница 12: ...5 POWER CABLE ON OFF SWITCH BATTERY PACK POWER SUPPLY OS136 Dimensions mm in OUTPUT 1 mW WAVELENGTH 630 670 nm CLASS II 2 LASER PRODUCT COMPLIES WITH FDA 21CFR 1040 10 EN60825 1 11 2001 LASER RADIATIO...

Страница 13: ...uirements Min Load 0 to 5 Vdc 1 K Ohms Min Load 0 to 10 Vdc 2 K Ohms Max Load 4 to 20 mA Power Supply 4 20 mA Min Load 10 mV Deg 10 K Ohms Min Load K T C 100 K Ohms Operating Ambient Temperature No Wa...

Страница 14: ...er Beam Diameter Less than 5 mm Beam Divergence Less than 2 mrad Operating Temperature 0 to 50 C 32 to 122 F Operating Relative Humidity Less than 95 RH non condensing Power Switch ON OFF Slide switch...

Страница 15: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Страница 16: ...ity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Отзывы: