background image

3

z

LARGE LED DISPLAY READABLE TO 180 FEET

z

VARIOUS ANALOG INPUT MODULES;

DC VOLTAGE AND CURRENT
PROCESS SIGNALS
TRUE RMS VOLTAGE AND CURRENT
THERMOCOUPLE OR RTD
STRAIN GAGE/BRIDGE

z

ALARMS, ANALOG OUTPUT, AND COMMUNICATION

z

PROGRAMMABLE USER INPUTS

z

UNIVERSAL AC POWERED (85 to 250 VAC)

z

PROGRAMMING SOFTWARE

z

NEMA 4X/IP65

GENERAL DESCRIPTION

The LDP63100 is a versatile display that can increase productivity by

offering the plant floor or production area a large visual display of their current
status. Whether your measurement is voltage, current, process, temperature, or
strain gage, the LDP63100 can satisfy your requirement. Plug-in option cards
can add alarms, analog output, and communication/bus capabilities, making the
LDP63100 a truly Intelligent Panel Meter.

SAFETY SUMMARY

All safety regulations, local codes and instructions that appear in this and

corresponding literature, or on equipment, must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment connected
to it. If equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.

The protective conductor terminal is bonded to conductive

parts of the equipment for safety purposes and must be
connected to an external protective earthing system.

SPECIFICATIONS

Input specifications, wiring, and programming information is contained in
the corresponding literature shipped with the ordered model.

1. 

DISPLAY

: 4" (101 mm) Red LED

5-Digit: -19999 to 99999

2. 

POWER REQUIREMENTS

:

AC Input Modules: 85 to 250 VAC, 50/60 Hz, 18 VA
LDP63100 Display: 85 to 250 VAC, 50/60 Hz, 10 VA

3. 

ANNUNCIATORS

:

Display Indication

: Three vertical dots on the left side of the unit identify

the displays for the following modes:

Setpoint Indication

: Four vertical dots on the right side of the unit identify

the setpoint “ON” condition, with SP 1 being the top position through SP
4 at the bottom.

4. 

LDP63100 Programming

: The unit is a large display, designed to be

remotely mounted. Therefore, the unit does not have a programming keypad.
Unit programming should be accomplished by one of the following methods:

Rear Terminal Block

: External switches can be wired via the terminal block

to allow unit programming. A minimum of 3 switches would be required.

Optional Programming Remote  (LDP6-PGM)

: This option provides a 10

foot interconnecting cable and programming box. The Programming
Remote contains buttons allowing easy programming of the display.

Optional Serial Programming

: You can purchase an RS232 or RS485 Comms

Card and program the unit via Crimson, a Windows

®

based software

program.

DIMENSIONS  In inches (mm)

CAUTION: Risk of Danger

Read complete instructions prior to

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

TOP

Maximum

MIDDLE

Minimum

BOTTOM

Total

C

US LISTED

UL

R

IND. CONT. EQ.

51EB

Содержание LDP63100

Страница 1: ...L LD DP P6 63 31 10 00 0 Extra L Large D Display omega com e mail info omega com For latest product manuals omegamanual info User sGuide Shop online at LP0689X...

Страница 2: ...megashop cz Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United Kingdom One Omega D...

Страница 3: ...IFICATIONS Input specifications wiring and programming information is contained in the corresponding literature shipped with the ordered model 1 DISPLAY 4 101 mm Red LED 5 Digit 19999 to 99999 2 POWER...

Страница 4: ...CATIONS AND COMPLIANCES SAFETY UL Recognized Component File E313607 UL61010A 1 CSA C22 2 No 1010 1 Recognized to U S and Canadian requirements under the Component Recognition Program of Underwriters L...

Страница 5: ...ewdriver blade 3 16 or 1 4 into the narrow slot between the LDP63100 rear cover plate and the module s plastic cover as illustrated in Figure 1 Twist the screwdriver in the direction shown to disengag...

Страница 6: ...nstall 14 10 32 keps nuts supplied and tighten evenly for uniform gasket compression Do not over tighten the nuts By using additional mounting accessories the LDP63100 can be surface wall mounted susp...

Страница 7: ...via the terminal block to allow unit programming A minimum of 3 switches would be required Each external switch must be wired between the key and the common terminal Optional Programming Remote LDP6 P...

Страница 8: ...them 90 degrees clockwise until the notches engage with the lips of the channel The bolts and washers provided allow mounting to surfaces to thick 6 4 to 12 7 mm Use longer bolts for mounting to thick...

Страница 9: ...the instructions included with the personality board 7 Remove the center section of the rear panel gasket Apply the gasket to the rear panel of the enclosure by inserting the 8 32 screws through the p...

Страница 10: ...C power LDP63100 DC True RMS AC Current and Volt Inputs 85 250 VAC power LDP63100 AC Process Input 85 250 VAC power LDP63100 E Strain Gage Input 85 250 VAC power LDP63100 S ACCESSORIES LDP631 SHR Shro...

Страница 11: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Страница 12: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...

Отзывы: