Interpreting the data in a block
:
Each block includes integer weight values separated by a c/r.
In order to get the real weight values, the integer values
should be multiplied by the current
Resolution Factor
(for
details refer to the end of stage 3, above). You may get the current
Resolution Factor using the method:
LCICwim_commands1.Get_Resolution_Factor
4.3.5 Misc.
Apply_Temporary_Zero()
Manually zero the gross weight. The effect of this function is temporary
— it expires upon card reset.
Reset_Board()
Resets the board. Usually this function is not required.