background image

OMEGAnet

SM

 On-Line Service

http://www.omega.com

Internet e-mail

[email protected]

Servicing North America:

USA:

 ISO 9001 Certified

Canada:

One Omega Drive, Box 4047

976 Bergar

Stamford, CT 06907-0047

Laval (Quebec) H7L5A1

Tel: (203) 359-1660

Tel: (514) 856-6928

FAX: (203)359-7700

FAX: (514) 856-6886

e-mail: [email protected]

e-mail: [email protected]

omega.com

TM

For immediate technical or application assistance:

USA and Canada:

Mexico and Latin America:

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

SM

Tel: (95) 800-TC-OMEGA

SM

Customer Service: 1-800-622-2378 / 1-800-622-BEST

SM

FAX: (95) 203-359-7807

Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

SM

En Español: (203) 359-7803

TELEX: 996404  EASYLINK: 62968934  CABLE: OMEGA

e-mail: [email protected]

Servicing Europe:

Benelux:

Germany/Austria:

Postbus 8034, 1180 LA Amstelveen,

Daimlerstrasse 26, D-75392

The Netherlands

Deckenpfronn, Germany

Tel: (31) 20 6418405 FAX: (31) 20 6434643

Tel: 49 (07056) 3017 FAX: 49 (07056) 8540

Toll Free in Benelux: 06 0993344

Toll Free in Germany: 0800 82 66342

e-mail: [email protected]

e-mail: [email protected]

Czech Republic:

United Kingdom:

 ISO 9002 Certified

ul. Rude armady 1868, 733 01 Karvina-

One Omega Drive

Hranice, Czech Repubic

Riverbend Technology Centre Northbank, Irlam,

Tel: 420 (69) 6311627 FAX: 420 (69) 6311114

Manchester, M44 5EX, England

e-mail: [email protected]

Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622

France:

9, rue Denis Papin, 78190 Trappes

Toll Free in England: 0800-488-488

Tel: (33) 130-621-400 FAX: (33)130-699-120

e-mail: [email protected]

Toll Free in France: 0800-4-06342

e-mail: [email protected]

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification
of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains,
and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient connected application.

Содержание HH501AR

Страница 1: ...OMEGA HH501AS HH501BS HH501AR HH501BR Digital Thermometer...

Страница 2: ...l Free in Germany 0800 82 66342 e mail nl omega com e mail germany omega com Czech Republic United Kingdom ISO 9002 Certified ul Rude armady 1868 733 01 Karvina One Omega Drive Hranice Czech Repubic R...

Страница 3: ...CAUTION Repeated sharp flexing can break the thermocouple leads To prolong lead life avoid sharp bends in the leads especially near the connector INTRODUCTION This instrument is a 3 digit compact size...

Страница 4: ...ns 195mm H x 92mm W x 53mm D Weight 365g Input Connector Accepts standard miniature thermocouple connectors flat blades spaced 7 9mm center to center Battery Life 100 hours typical battery Auto power...

Страница 5: ...us or Fahrenheit user selectable Measurement Range 0 C to 1767 C 32 F to 1999 F Resolution 1 C 1 F Accuracy Accuracy is specified for operating temperatures over the range of 18 C to 28 C 64 F to 82 F...

Страница 6: ...the temperature scale press the C or F key Button Press button to toggle on and off of backlight The backlight will switch off automatically after 30 seconds HOLD Mode Pressing the HOLD key to enter t...

Страница 7: ...of readings all values are frozen press again to restart recording To prevent accidental loss of MIN MAX MAX MIN and AVG data in this mode can only be cancelled by pressing and hold down the MIN MAX...

Страница 8: ...Relative mode zero the display and store the displayed Reading as a reference value and annunciator REL is displayed Press REL key again to exit the relative mode The relative value can also be entere...

Страница 9: ...scape Hi Limit value set mode _ is displayed the is displayed when you set up the fourth number Hi Limit value is entered via overlay numbers when you want to get negative values push 0 key for end of...

Страница 10: ...ic power off feature is disabled and other funtion key are disabled when input temperature value exceed Hi The beeper emits a continuity pulse tone and Hi is displayed and when input temperature value...

Страница 11: ...eter before removing the cover Battery Replacement Power is supplied by a 9 volt transistor battery NEDA 1604 IEC 6F22 The appears on the LCD display when replacement is needed To replace the battery...

Страница 12: ...on J1 position 2 Input DCV 25 6mV to the T1 after the display is stabilized forward 4 digits then press ENTER key and 01 is displayed 3 Input DCV 74mV after the display is stabilized then press ENTER...

Страница 13: ...ty or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipmen...

Страница 14: ...Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conductivi...

Отзывы: