pg. 4, OMB-DBK Basics
02-19-02
Daq Systems
Expansion and Terminal Panel Connection DBKs
The following DBKs offer provide various expansion and connection options. The stackable 3-slot
DBK10 low-profile enclosure can be used for up to three DBKs. If a system has more than 3 DBKs, the
10-slot DBK41 can be used. Several DBK41s can be daisy-chained to accommodate many DBKs in one
system.
Expansion and Connection, General
Product
Name/Description
I/O
Connectivity
DBK1
16-Connector BNC Adapter Module
16 connectors
P1
DBK10
3-Slot Expansion Chassis
3 cards
P1, P2, or P3
DBK11A
Screw-Terminal Option Card (DB37-Screw Terminal Block)
Component
sockets
P1
DBK40
BNC Interface
18 connectors
P1 or P3
DBK41
Analog Expansion Enclosure
10 cards
P1 or P2
DBK60
Expansion Chassis with Termination Panels
3 cards
P2
Termination Panels, Connectivity for DaqBoard/260
Product
Name/Description
I/O
Connectivity
DBK601 Termination
Panel
- blank rear panel
none
none
DBK602
Termination Panel - BNC rear panel
16 connectors
BNC
DBK603
Termination Panel - Safety Jacks, single ended
16 connectors
Safety Jacks
DBK604
Termination Panel - Safety Jacks, differential
8 differential (16)
Safety Jacks
DBK605
Termination Panels - Thermal Couple, differential panels;
specify type: B, J, K, R, S, or T
16 differential
T/C Connectors
DBK606
Termination Panel – 3 Terminal Blocks; 16 connections per TB
48 connectors Screw
Terminal
DBK607
Termination Panel – strain relief clamp
none
none
DBK608
Termination Panel – 3 female DB37 connectors
three DB37
DB37
Power Supply DBKs
Power supply type DBKs are typically used in laboratory, automotive, and field applications. Input power
can come from any +10 to +20 VDC source, or from an AC source by using an appropriately rated AC-to-
DC adapter. The DBK30A rechargeable power supply can power DBK modules where AC mains are not
available (the DBK30A outputs 28 V for powering transducers). For a large number of DBK cards, the
DBK32A or DBK33 can be installed into an expansion slot. The DBK33 is used when +5 V is required in
addition to ±15 VDC. The DBK34 provides a steady 12 or 24 VDC while working with vehicle electrical
systems that may be turned on or off during testing.
Power Supply
Product
Name/Description
Power
DBK30A
Rechargeable Battery/Excitation Module
+12-14, 24-28 VDC (3.4 A-hr @ 14 VDC)
DBK32A
Auxiliary Power Supply Card
±15 V @ 500 mA
DBK33
Triple-Output Power Supply Card
±15 V @ 250 mA; +5 V @ 1 A
DBK34
Vehicle UPS Module
12/24 VDC (5 A-hr @12 VDC)
DBK34A
UPS Battery Module
12/24 VDC (5 A-hr @12 VDC)
Tips on Setting up a Data Acquisition System
A successful installation involves setting up equipment and setting software parameters. In addition to this
manual, you may need to consult your Daq device or LogBook user’s manual.
DBKs should be configured before connections are made and power is applied. This sequence can prevent
equipment damage and will help ensure proper operation on startup. Many DBKs have on-board jumpers
and/or DIP switches that are used for setting channels and other variables. You will need to refer to the
individual DBK document modules to ensure that the DBKs are properly configured for you application.
Prior to designing or setting up a custom data acquisition system, you should review the following tips.
After reviewing the material you can write out the steps to setup a system that will best meet your specific
application needs.
Содержание 100/200 Series
Страница 4: ...vi 10 29 02 OMB DaqBook User s Manual ...
Страница 6: ...viii 10 29 02 OMB DaqBook User s Manual ...
Страница 46: ...pg 12 OMB DBK Basics 02 19 02 Daq Systems ...
Страница 48: ...A 2 02 14 02 Appendix A Specifications DaqBooks This page is intentionally blank ...
Страница 50: ...A 4 02 14 02 Appendix A Specifications DaqBooks ...