Water Drainage 

This  air  condition  has  an  auto-water-evaporating  system.  Condensed-water  cycle  is 

used to cool down the condenser, which not only improves cooling efficiency, but also 

saves energy. 

• 

When water in the water pan exceeds the warning level, the air condition will 

automatically sound an alarm, and the LCD temperature display area will show 

"FL". At this point, you need to move the drainage pipe connecting the air 

condition or the water outlet to sewer or other drainage area to empty the 

water. 

• 

Shut off the air condition and unplug. Try not to move the model abruptly as 

this may cause water to spill out from internal water tank. 

• 

Place a tray under the water plug. 

• 

Screw off the drain plug and unplug the water rubber stopper 

- water will drain from the container. 

• 

Put the water rubber stopper back and screw the drain 

• 

Plug cap back into place After the water is emptied, the air condition will 

automatically return to the original state. 

 

• 

Continuous Drainage  

 

 

When you plan to leave this air conditioner unused for a long time, please remove the rubber 
blockage from the drainage hole at the middle of the air conditioner, and connect a drain 
hose (supplied with the unit) as shown below. The other side of the hose can be placed in 
the sink and the water drained. 

 

 

If water pump is damaged, continuous drainage can be used, and under this condition, the 
water pump is not activated. The air conditioner can also work well. 

Содержание OAPC1617

Страница 1: ...OAPC1617 PORTABLE AIR CONDITIONER...

Страница 2: ...tents 2 Important Safeguards 3 4 Placement and Installation 5 6 Parts List 6 7 Control Panel 8 Remote Control 9 Operation Methods 9 10 Water Drainage 11 Maintenance 12 Troubleshooting 13 Technical Dat...

Страница 3: ...hould be supervised to ensure that they do not play with the appliance If the power cord is damaged it must be repaired by an authorised agent of Omega Altise SAFETY RULES To prevent injury to the use...

Страница 4: ...with anything but fingers Do not remove fixed covers Do not use this air condition if it is malfunctioning or has been dropped or damaged Never use the power point switch to start or stop the air con...

Страница 5: ...ctor counter clockwise Put slide bar connector into adjustable slide bar adjust window open width in order slide bar match window well and the length of slide bar is adjustable figure 2 FIGURE 1 Insta...

Страница 6: ...ly the exhaust pipe supplied Longer or extended pipes may damage the appliance Note Maximum length of unfolding exhaust pipe is 1500mm please shorten the length as much as possible and keep it level a...

Страница 7: ...7 Parts List...

Страница 8: ...4 DISPLAY WINDOW Display window will show the temperature and mode setting when the air condition is operational 5 DOWN under cooling mode press this key to decrease setting temperature from 16 31C un...

Страница 9: ...used Press MODE to select cooling mode cooling mode inductor turns on Press UP or DOWN to adjust temperature from 16 to 31 Press FAN to select high medium or low fan speed Fan mode Press MODE to selec...

Страница 10: ...ter the selected time If you adjust the timer or press the power key previous settings will be cleared Timer functions cannot be combined or repeated Dehumidifying mode Press MODE to select dehumidify...

Страница 11: ...l out from internal water tank Place a tray under the water plug Screw off the drain plug and unplug the water rubber stopper water will drain from the container Put the water rubber stopper back and...

Страница 12: ...air condition it will cause damage Seasonal Cleaning If the air condition is not being used for a long time please follow these steps Pull out drainage plug upper lower to empty any water out Let the...

Страница 13: ...other sources of heat Close doors and windows and add new air conditioning The filter screen is dirty Clean or replace the filter screen The air inlet or outlet is blocked Clear obstructions Big Noise...

Страница 14: ...odel OAPC1617 Cooling capacity BTU h 16000 Mains Power consumption W 1700 Current A 6 Refrigerant R410A Compressor Rotary Fan speeds 3 Thermostat 16 31 Timer h 0 24 Dimensions W H D mm 420 722 360 Net...

Страница 15: ...Appendix A Circuit Diagram...

Страница 16: ...Omega Altise products are distributed in Australia by Shriro Australia Pty Ltd Locked Bag 5002 Kingsgrove NSW 2208 Phone 1300 795 572 Fax 02 9415 5525 Web http www omegaaltise com au...

Отзывы: