Omega Altise OAPC14W Скачать руководство пользователя страница 11

 

 

OMEGA ALTISE 

 

 

INSTALLATION INSTRUCTIONS 

 

 

 

 

Choose your location 

 

 

If tipped more than 45°, allow the unit to set upright for at least 24 hours before starting up.

 

 

 

Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for 

proper air circulation. 

 

Do not operate in close proximity to walls, curtains, or other objects that may 

block air inlet and outlet. Keep the air inlet and outlet free of obstacles. 

 

Never install the unit where it could be subject to

 

 

I.

 

Heat sources such as radiators, heat registers, stoves or other products that 

produce heat. 

II.

 

Direct sunlight 

III.

 

Mechanical vibration or shock 

IV.

 

Excessive dust 

V.

 

Lack of ventilation, such as cabinet or bookcase 

VI.

 

Uneven surface 

WARNING!  

 

 

Install the unit in rooms which exceed 4 m². 

 

Do not install the unit in a place where inflammable gas may leak. 

 

 

 

ATTACH THE EXHAUST HOSE 

 

The air conditioner requires being vented outside so that the exhaust air can escape the room which coming 

from the appliance contains waste heat and moisture.  

 

Do not replace or extend exhaust hose which will result in decreased efficiency, even worse shut down the unit 

due to low backpressure.  

 

Step 1:  Connect the hose connector to one end of the exhaust hose. 

 

 

 

 

 

 

 

 

 

 

 

 

11 

Содержание OAPC14W

Страница 1: ...OMEGA ALTISE OPERATION MAINTENANCE AND SAFETY INSTRUCTIONS FOR OMEGA ALTISE AIR CONDITIONER Model OAPC14W...

Страница 2: ...LTISE Contents IMPORTANT SAFETY INSTRUCTIONS 3 TECHNICAL DETAILS 8 FEATURES 9 PRODUCT OVERVIEW 9 INSTALLATION INSTRUCTIONS 10 OPERATING INSTRUCTIONS 14 CLEANING 18 SERVICING 20 TROUBLESHOOTING 22 WARR...

Страница 3: ...the air inlet or the aluminum fins of the unit Do not operate the unit if it is dropped damaged or showing signs of product malfunction Do not clean the appliance with any chemicals Ensure the unit i...

Страница 4: ...e shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation WARNING Do not use means to accelerate the defrosting process or to clean other...

Страница 5: ...om a leak Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also take into account th...

Страница 6: ...lowed Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in t...

Страница 7: ...omplete with pressure relief valve and associated shut off valves in good working order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shal...

Страница 8: ...ion systems or contact the retailer where the product was purchased They can take this product for environmentally safe recycling TECHNICAL DETAILS Model OAPC14W Fan Speeds 3 settings Cooling Capacity...

Страница 9: ...t Auto shut off when tank full Automatic restart in the event of power outage Auto defrosting function at low ambient temperatures Remote control 3 speed fan Casters for easy mobility PRODUCT OVERVIEW...

Страница 10: ...S Unpacking Unpack the carton and take the appliance and accessories out Check the device after unpacking for any damage or scratches on it Accessories 1 Exhaust hose 2 Hose connector 3 Window kit ada...

Страница 11: ...radiators heat registers stoves or other products that produce heat II Direct sunlight III Mechanical vibration or shock IV Excessive dust V Lack of ventilation such as cabinet or bookcase VI Uneven...

Страница 12: ...kit the length of your window Connect the exhaust hose to the window kit Step 4 Close your window to secure the kit in place It needs to hold the windows kit firmly in place secure the window kit wit...

Страница 13: ...the hose connector to the exhaust air outlet of unit Step 6 Adjusting the length of the flexible exhaust hose and avoid bends in the hose Then place AC near an electrical outlet Step 7 Adjust the lou...

Страница 14: ...4 SLEEP MODE Press this button to turn the night mode on or off 5 DOWN Press this button to reduce the temperature or timer settings to the desired value 6 SWING Set the vertical air flow direction 7...

Страница 15: ...tional on the remote control COOLING MODE Select the cool mode to lower the temperature in your room Press MODE button repeatedly until the LED of COOL operation lights up Press ADD MINUS button to ad...

Страница 16: ...e control the LED of DRY operation lights up The fan speed is unable to select User should connect the hose to the drain outlet at the bottom of the unit Note In this mode the fan speed switches over...

Страница 17: ...e self evaporating system uses the collected water to cool the condenser coils for better efficient performance There is no need to empty the drainage tank in cooling operation except in drying operat...

Страница 18: ...cleaning The air filter is removable for easy cleaning Do not operate the unit without an air filter or the evaporator may be contaminated 1 Press POWER button to switch off the unit and unplug the po...

Страница 19: ...on equipment PPE 4 Evacuate unnecessary personnel isolate and ventilate area 5 Do not get in eyes on skin or on clothing Do not breathe vapours or gas 6 Prevent entry to sewers and public waters 7 Sto...

Страница 20: ...n system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion...

Страница 21: ...e safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If the fault cannot be corrected immediately but it is necessary to continue operation an ade...

Страница 22: ...re transport Check if the drain hose is kinked or bends Straighten the hose to avoid a trap existing Excessive Noise Check if the unit is securely positioned Place the unit on horizontal and firm grou...

Страница 23: ...ed to a warranty of Twelve 12 months covering all parts with Three 3 months on any labour cost of service or repair WHAT IS COVERED By Our Warranty During the warranty period Omega Altise or its autho...

Страница 24: ...OMEGA ALTISE A division of Shriro Australia Pty Ltd 2 34 Davidson Street Chullora NSW 2190 In Australia 1300 795 572 In New Zealand 09 415 6000 www omegaaltise com IM Ref OAPC14W 2021 09 02 24...

Отзывы: