CORRECTION FACTORS
To calculate the correct capacity of a given filter based on actual operating conditions, multiply the nominal
flow capacity by the appropriate correction factor(s).
CORRECTED CAPACITY = NOMINAL FLOW CAPACITY x C
OP
x C
OT
x C
D
OPERATING PRESSURE
[bar]
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
[psi]
29
44
58
72
87
100
115
130
145
160
174
189
203
218
232
C
OP
0,38 0,5 0,63 0,75 0,88
1
1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
OPERATING TEMPERATURE
DEW POINT
[°C]
25
30
35
40
45
50
55
60
[°C]
-25
-40
-70
[F]
77
86
95
104
113
122
131
140
[F]
-13
-40
94
C
OT
1
1
1
0,97
0,87
0,80
0,64
0,51
C
D
1,1
1
0,7