background image

AOK 20SS - Installation and operating manual 

 

 

Technical data 

 

 
 

 

 

 
CALCULATION OF CAPACITY 

For rough calculation of discharge capacity at certain pressure use following equation: 

𝑄 = 63√∆𝑝

    

Example: if operating at 7barg;  

𝑄 = 63√7 = 166,7

 

 

MATERIALS 

Housing material 

Stainless steel 1.4404 

Fittings, Screws 

Stainless steel 1.4404 / A4 

Floater 

Stainless steel 1.4404 

Sealing 

NBR 

 

 

 

Operation pressure range 

0 – 20 bar / 0 – 290 psi 

Minimum reccomended operating pressure 

1,5bar (g) 

21,8 psi 

Drain capacity (7 bar / 101 psi) 

167 l/h 

0,1 scfm 

Drain capacity (16 bar / 235 psi) 

252 l/h 

0,15 scfm 

Operating temperature range 

1,5 – 65°C 

35 - 149 °F 

Operating media 

Condensate (air, water, oil); Non-agressive 

Inlet connection 

G ½” (NPT on request) 

Outlet connection 

G ½” (NPT on request) 

Reservoar volume 

0,45 l 

Mass 

6,6 kg 

Dimensions A x B x C [mm] 

155 x 100 x 100 

Valve type 

Direct acting, Normally closed 

Discharge orifice cross cection 

1,8mm 

0,0708 inch 

Содержание AOK 20SS

Страница 1: ...al Please read the following instructions carefully before installing the product Trouble free and safe operating of the product can only be guaranteed if recommendations and conditions stated in this...

Страница 2: ...ing sealing 5 1x Float holder 6 1x Nozzle 7 1x Flat seal 8 1x Housing 9 1x Plug 10 1x Test button 11 1x O ring sealing 12 1x Lever holder 13 1x Circlip external 14 1x M4 screws 15 1x Lever 16 1x Float...

Страница 3: ...ling NBR Operation pressure range 0 20 bar 0 290 psi Minimum reccomended operating pressure 1 5bar g 21 8 psi Drain capacity 7 bar 101 psi 167 l h 0 1 scfm Drain capacity 16 bar 235 psi 252 l h 0 15 s...

Страница 4: ...data label Do not use the device in hazardous areas with potentially explosive atmospheres Use original spare parts only Use the device for the appropriate purpose only Appropriate use AOK 20SS serie...

Страница 5: ...nection When condensate level drops floater drops with it and blocks the discharge orifice This operation prevents air loss On the front side of the AOK 20SS is a TEST button which if rotated in a clo...

Страница 6: ...with condensate It is recommended to install a ball valve between the device and the system This is done to ensure easy maintenance work on the device without the needed to empty the entire system In...

Страница 7: ...nded to clean the reservoir at least once a year Sealing elements are subject to wear which depends on various operating parameters such as pressure temperature dirt content etc It is also recommended...

Страница 8: ...8 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 0 1 200 68 50 E mail info omega air si www omega air si...

Отзывы: