Introduction 

 

External heat recovery system AirWatt is intended for professional use. This user manual 
provides all necessary information for dimensioning, installation, safe operation and 
maintenance. It should be read thoroughly and carefully. Obey all safety instructions. 
Manual should be conserved through entire lifetime of device. Regular and correct 
maintenance and regular safety checks are required for long and trouble free operation. 

Installation and use may be subject of local laws and directives which must be obeyed. For 
any further information or in case of doubt contact manufacturer. Manufacturer will not be 
held responsible for any defects, which are consequence of misinterpreting user manual 
instructions, unprofessional installation or disobeying local laws and directives. 

General safety instructions 

 

Warning! 
Operating this device may be dangerous, if following instructions are 
not obeyed. In addition to  this manual  instructions  from compressor 
manufacturer must also be observed. 

 
AirWatt unit was designed and manufactured in accordance with all health and safety 
requirements of EU. 
 

 

All personnel involved at installation, operating and maintenance of this device must 
reed and fully understand this included instructions. 

 

Installation and assembly of the unit can only be performed by authorized personnel 
of company Omega Air d.o.o. Ljubljana. 

 

Device may only be used in accordance to this manual. 

 

Personnel must always wear personal protective equipment. 

 

Do not use this device, if there are present any signs of damage or defect. 

 

Always turn of compressor, lock the power supply and depressurize the system, 
before performing any kind of work on device or installation. 

 

Device must have installed limiting elements, which prevent operating outside 
specified parameters. 

 

It is forbidden to approach device under operation. 

Installation and maintenance work on the device my only be carried by authorized and 
trained professional. 

 

It is forbidden to alter the device or its construction in any way. 

 

Before maintenance depressurise the system. 

 

Use only original spare parts. 

 

Use the device only for the purpose for which it was originally designed. 

Содержание AirWatt

Страница 1: ...rnal Heat Recovery Please read the following instructions carefully before installing indicator into service Trouble free and safe operating of the unit can only be guaranteed if recommendations and c...

Страница 2: ...AirWatt Installation and operating manual Components Part 1 Plate chiller 2 Thermostat head 3 Temperature sensor input output 4 Connection oil water 4 2 3 4 3 1...

Страница 3: ...ials Housing Steel sheet metal External protection Powder paint coated Epoxy polyester base Heat exchanger Stainless steel Pipes Copper Connection Brass copper Support NBR Technical specification Oper...

Страница 4: ...essor manufacturer must also be observed AirWatt unit was designed and manufactured in accordance with all health and safety requirements of EU All personnel involved at installation operating and mai...

Страница 5: ...crucial for safe and long operation of screw compressor Water does not start to flow until oil temperature reaches set value Switch on temperature of thermostatic valve can be set between 60 C and 90...

Страница 6: ...ir or by authorized and trained professional Compressor oil circuit is required Establish pipe connection between compressor and AirWatt unit Replenish oil in compressor separator to prescribed level...

Страница 7: ...r moderately polluted water 3 years for relatively clean water For cleaning oil sediment and grease it is recommended to use paraffin for cleaning limestone it is recommended to use acetic or citric a...

Страница 8: ...get flow temperature press the left or right button A 2 Press the middle button shortly to confirm new target temperature B Advanced Settings 1 Press middle button for 5 seconds to reach advanced sett...

Страница 9: ...m flow temperature by pressing the left or right button OK 4 Press down the middle button for 5 seconds to return to main menu Minimum Flow Temperature 1 To change the minimum flow temperature press t...

Отзывы: