AFs - Installation and operating manual 

B

C

(6

4

)

A

G 1/2"

D

Technical data 

 

FILTER 

HOUSING 

PIPE SIZE 

[inch] 

FILTER 

ELEMENT 

FLOW CAPACITY 

DIMENSIONS [mm] 

VOLUME 

[l] 

WEIGHT 

[kg] 

[Nm

3

/h] 

[scfm] 

AF 0056 

3/8” 

06050 

60 

35 

192 

88 

25 

60 

0,49 

0,6 

AF 0076 

1/2” 

07050 

78 

46 

192 

88 

25 

60 

0,49 

0,6 

AF 0106 

3/4” 

14050 

120 

70 

262 

88 

25 

80 

0,68 

0,7 

AF 0186 

1” 

12075 

198 

116 

264 

125 

39 

100 

1,57 

1,2 

AF 0306 

1” 

22075 

335 

197 

364 

125 

39 

120 

2,1 

1,6 

AF 0476 

1 ½” 

32075 

510 

300 

464 

125 

39 

140 

2,7 

1,9 

AF 0706 

1 ½” 

50075 

780 

459 

644 

125 

39 

160 

3,8 

2,6 

AF 0946 

51090 

1000 

588 

696 

164 

50 

520 

6,1 

5,7 

AF 1506 

76090 

1500 

882 

943 

164 

50 

770 

8,3 

7,6 

AF 1756 

2 ½” 

76090 

1680 

990 

943 

164 

50 

770 

8,4 

7,3 

AF 2006 

3” 

51140 

2160 

1270 

801 

242 

60 

630 

16,7 

14,1 

AF 2406 

3” 

75140 

2760 

1620 

998 

242 

60 

780 

21,3 

16,7 

 

Operating temperature 

1,5 - 65 °C 

35 - 149 °F 

Operating pressure

 

0 - 16 bar(g) 

0 - 232 psi 

 

MATERIALS 

Housing material 

Aluminium 

Fittings, Screws 

Brass, Brass-zinc plated, Steel 

Cover 

ABS 

Sealing 

NBR 

Corrosion protection 

Anodized (optional) 

Outside protection 

Powder paint coated (Epoxy-polyester base) 

Lubricant 

 

CORRECTION FACTORS

 

To calculate the correct capacity of a given filter based on actual operating 
conditions, multiply the nominal flow capacity by the appropriate correction 
factor(s).  
CORRECTED CAPACITY = NOMINAL FLOW CAPACITY x C

OP 

 

[bar] 

10 

11 

12 

13 

14 

15 

16 

[psi] 

29 

44 

58 

72 

87 

100 

115 

130 

145 

160 

174 

189 

203 

218 

232 

C

OP 

0,38 

0,5 

0,63  0,75  0,88 

1,13  1,25  1,38  1,50  1,63  1,75  1,88  2,00  2,13 

 

PRESSURE EQUIPMENT DIRECTIVE PED 2014/68/EU (Fluid group 2) 

 

 

There is Technical datasheet available. For additional technical specification, contact 
manufacturer. 

 

AF 0056 - AF 0476 

Not required 

AF 0706 - AF 1506 

Category 1, Module A 

AF 1756 - AF 2406 

Category 2, Module H 

Содержание AF Series

Страница 1: ...rating manual AFs compressed air filter Please read the following instructions carefully before installing filter into service Trouble free and safe operating of the filter can only be guaranteed if r...

Страница 2: ...and operating manual 2 Components Part 1 Pressure drop indicator optional 2 Head cover 3 Filter head 4 Housing sealing 5 Filter element 6 Filter bowl 7 Sight window optional 8 Condensate drain optiona...

Страница 3: ...Operating temperature 1 5 65 C 35 149 F Operating pressure 0 16 bar g 0 232 psi MATERIALS Housing material Aluminium Fittings Screws Brass Brass zinc plated Steel Cover ABS Sealing NBR Corrosion prot...

Страница 4: ...t is necessary to ensure that the unit is equipped with the corresponding safety and test devices to prevent the permissible operating parameters from being exceeded Filter has been designed for a pri...

Страница 5: ...mage resulting from improper incorrect or unreasonable use Use genuine spare parts only Any damage or malfunction caused by the use of ungenuine parts is not covered by Warranty or Product Liability I...

Страница 6: ...icator or the Differential Pressure Gauge optional on the filter head Connect the filter head to the compressed air piping and check that the airflow corresponds to the direction of the arrow position...

Страница 7: ...minutes close the drain valve and slowly open the on off valve V1 down line from the filter Operation Ensure trouble free operation of condensate drain Check At least once a week if condensate drain...

Страница 8: ...l operating environment After 10 years periodical checks of filter integrity are strongly recommended for safe operation Carry out a check for leaks once the maintenance work has been finished Warrant...