It is possible to program only the boiling phase by setting 0°C as preheating temperature
(phase no. 1).
For boiling it is necessary to set FULL as boiling temperature (phase 2).
If the boiling temperature is set on FULL, the rising speed is automatically set on FULL.
The rising speed values do not correspond to °C/min but they refer to numbers of a scale where
the max. value is FULL (heating element always working).
The set value is the time measured in seconds where the heating element works for a 20 second
period time and these time periods repeat until the temperature set is reached.
I.E. if 12 it the value is, the heating element works cycling for 12 seconds and it stays OFF
for 8 seconds until the temperature set is reached.
The rising speed parameter has also to be set considering the water contained in the
polymerization tank (the bigger is the quantity of water the highest will has to be the value
set9:
SIDE III INSTALLATION AND USE INSTRUCTIONS
INTRODUCTION
Before starting-up the machine, follow precisely the following instructions.
Make sure that your electric equipment has a good earth and that it is in conformity with the
2006/95/EC - Low Voltage.
3.1.1 INSTALLATION
-
Verify the apparatus has not stood any evident damage during transportation.
-
Place the apparatus on a stable horizontal non flammable surface away from any water
sprayings and from flammable materials. The polymerizing unit has to be placed on a
sufficiently wide surface to allow proper ventilation.
-
Fit the muffles in the tank and put water in the tank with a container till the muffles are
covered up.
-
The machine has not to be used without water. The heating element has to be always covered by
the water (the minimal water level is up to the holed grille). Do not place the polymerizing
unit under a spout of water for any reason.
-
Before installation make sure the supply mains are in conformity with tag data (230 Vac –
50/60 Hz) and that the power line is protected by a differential thermo magnet switch. Also
check electrical inputs and powers installed. If you are not sure of what kind of power you
have, please contact the Electric Power Company. In particular, verify if the grounding
system is efficient.
-
Make sure the general switch is on OFF position (0), then connect the electric cable plug to
an electrical inlet.
3.2.1 PICTURE NO.1
1
2
3
6
5
4
7
8
- Page 2/9 -