Troubleshooting

There is not enough gas in the 

bag.

The bag is too small.

Select a bigger bag.

The programmed gas level is too 

low.

Increase the gas level value.

The bag is not correctly positioned 

over the gas outlets.

Adjust the bag position.

The machine does not seal.

The bag is not correctly positioned 

over the sealing beam.

Adjust the bag position.

The sealing wire is broken.

Replace the sealing wire.

The thermal safety of the power 

supply was tripped.

Wait until the safety resets, which 

can take half an hour. Decrease 

the sealing time.

The electrical contacts of the seal 

beam have fouled.

Remove the seal beam and clean 

the pins and contacts with sand 

paper.

The service symbol appears when 

turning on the machine, indicating 

the remaining production hours or 

cycles.

The service interval counters 

have reached their maximum 

programmed values.

To reset the service interval 

counters after the oil change: start 

the machine and while the display 

shows the hours or cycles, press 

and hold the “X” button.

Содержание VP-NL-0004-S

Страница 1: ...2023 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Tabletop Vacuum Packaging Models VP NL 0004 S 0008 S 0016 S 0021 S 0016 LL Items 50006 50007 50008 50009 50010 Inst...

Страница 2: ...General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty Registration Model VP NL 0004...

Страница 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 4: ...su sano juicio y no bajo alguna influencia de droga o alcohol y que este ha sido entrenado en el correcto funcionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci...

Страница 5: ...devices may never be by passed RESIDENTIAL USERS vendor assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in non commercial or reside...

Страница 6: ...S Model VP NL 0016 S VP NL 0021 S VP NL 0016 LL Seal Length 16 5 419mm 16 5 419mm x2 Vacuum Pump 16 m 21 m 16 m 10 Programmable Control No Yes No Maximum Product Height 7 178mm Useful Chamber Size 14...

Страница 7: ...Additional sealing pressure is usually recommended for MAP applications only The M40 M80 and the L10 L60 models with the option gas MAP are standard equipped with a compressed air inlet Extra sealing...

Страница 8: ...chine will complete a number of vacuum cycles before turning off automatically Stop function Stops the machine at any point in the packing cycle and aerates the chamber Reset function While programmin...

Страница 9: ...y be programmed for several additional functions Each of the 9 customizable programs is either 1 Time controlled 2 Sensor controlled TIME BASED OPERATION VACUUM GAUGE MBAR The values for vacuum and se...

Страница 10: ...cool down phase The machine will complete a number of vacuum cycles before turning off automatically Stop function Stops the machine at any point in the cycle and aerates the chamber Reset function W...

Страница 11: ...ing function as soon as product boiling is detected this prevents product loss through spillage and evaporation When turning off the machine with the button the symbol will start blinking on the LCD d...

Страница 12: ...e factory settings for the seal time is 2 seconds REVIEWING VACUUM TIME AND SEALING TIME 1 Press the button to display the programmed vacuum time the vacuum time is pre set at the factory 2 Press the...

Страница 13: ...mbar for a sensor based program and a sealing time of 2 seconds Program P H2O for liquid products When turning on the machine the pump will start After about 15 minutes of inactivity the pump will sto...

Страница 14: ...ir on off in seconds or in mbar only with sensor Multi cycle on off in number of cycles ADJUSTING ON OFF FUNCTION VALUES 1 Press the menu button to select the settings menu 2 Use the button to select...

Страница 15: ...osing the cover the pump continues to run for some time Any moisture in the oil of the pump will evaporate during this phase This increases the longevity of the machine and minimizes the need for oil...

Страница 16: ...necessary to loosen the beam 3 Remove the brown Teflon tape that is applied to the seal beam 4 Remove the two screws on the underside of the seal beam this releases the sealing wire 5 Clean the seal...

Страница 17: ...tom edge of the mounting plate 3 Position the wires across the seal beam and loosely install the second mounting plate 4 Carefully clamp the seal beam upside down in a bench vice 5 Pull the wires as t...

Страница 18: ...REPLACING SILICONE RUBBER SEAL OF COUNTER BEAM The rubber seal is clamped in the counter beam Replace the counter beam seal as follows 1 Pull the old rubber seal from the groove in the counter beam 2...

Страница 19: ...value is too high Lower the vacuum value in the program The packaging material is of poor quality Select a better quality packaging material The product damages the bag Program a higher value for sof...

Страница 20: ...wire The thermal safety of the power supply was tripped Wait until the safety resets which can take half an hour Decrease the sealing time The electrical contacts of the seal beam have fouled Remove t...

Страница 21: ...21 Parts Breakdown Model VP NL 0004 S 50006 Model VP NL 0008 S 50007...

Страница 22: ...Snap In STF42 for 50006 50007 127 29998 Hinge Bearing ST ST 6x255 for 50006 50007 53 27822 Castle Washer M3 for 50006 50007 81 30021 Thermal Fuse 4A for 50006 50007 128 29999 Hinge Part for 50006 5000...

Страница 23: ...23 Parts Breakdown Model VP NL 0016 S 50008 Model VP NL 0021 S 50009 Model VP NL 0016 LL 50010...

Страница 24: ...9 50010 24 27786 Flat Washer M6 D9021 A2 for 50008 50009 50010 42 35074 Thermal Fuse 10A for 50008 50009 50010 7C 65857 T4 Dekselsluiting for 50008 50009 50010 25 35978 Hexagon Nut M10 DIN934 A2 for 5...

Страница 25: ...25 Electrical Schematics Model VP NL 0004 S 50006 Model VP NL 0008 S 50007 Model VP NL 0016 S 50008 Model VP NL 0021 S 50009 Model VP NL 0016 LL 50010...

Страница 26: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 27: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Страница 28: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: