1.3 FOOD  SAFETY 

 

While many packaging machines are used  in applications involving vacuum packaging 

and vacuum cooking, there are inherent risks associated with these techniques that can result in 

serious  illness  or death to the consumer of the food product.   Therefore if you are using  

your machine  for  food applications,  you  must  consult a qualified food technician  or specialist   

in vacuum / modified atmosphere (M.A.P.) to review the safety of your application. 

 

 

GAS FLUSH

 

 

If your machine is equipped with gas flush (optional) and your application involves the use of 

gas flush to extend the shelf  life of your product you must consult a qualified food technician or 

specialist to review your application and develop a suitable gas mixture for your package. 

Further you must perform quality control and gas analysis on your final M.A.P. package. 

 

 

CLEANING 

 
 
 

Every  environment and application is different; therefore Omcan Inc. cannot provide 

cleaning procedure instructions that will guarantee microbiological sanitation. Therefore Omcan inc.

recommends that the purchaser of these machines consult with a sanitation expert to 

review your  procedures for cleaning the machine  while operating in your environment and with 

your specific product   to develop a robust cleaning schedule and methodology,followed by 

bacterial testing to ensure satisfactory cleaning is achieved. 

 

Содержание TC-420

Страница 1: ...TC 420 Table Top Vacuum Packaging Machine Operation Manual Version 6 9 1 ...

Страница 2: ...LEVEL 6 2 6 POWER CONNECTION 6 2 7 VACUUM PUMP ROTATION 6 3 OPERATION 7 3 1 VACUUM SETTING GUIDELINES 7 3 2 BASIC OPERATING INSTRUCTIONS 7 3 3 OPTIONAL DEVICE 7 3 3 1 GAS FLUSHING UNIT 7 4 MAINTENANCE 8 4 1 BASIC MAINTENANCE 8 4 1 1 DAILY VISUAL INSPECTION 8 4 1 2 DAILY CLEANING 9 4 2 VACUUM PUMP MAINTENANCE 9 4 3 SEAL BAR MAINTENANCE 9 10 4 4 MAINTENANCE INTERVAL CHART 11 5 TROUBLESHOOTING 12 5 1...

Страница 3: ...Explanation of Abbreviations F Front Seal LR Left Right Seal FC Front Seal with Hot Wire Cut off LRC Left Right Seal with Hot Wire Cut off ...

Страница 4: ...ily injury and or damage to the equipment Please fill in the information below You will find the information on the bill of lading and on the machines identification tag You will need this information when ordering replacement parts or making technical inquiries Model _____________________________ Serial ______________________________ Ship Date ____________________________ Owner __________________...

Страница 5: ...arried out only by qualified technicians or maintenance personnel 3 No service work should be attempted until the machine s power has been turned off All proper lock out tag out procedures should be followed 4 Do not put tools parts or other foreign objects on or into the machine 5 Always keep the machine clean lubricated and in good working condition 6 To provide protection against the risk of el...

Страница 6: ...electric shock hazard Explosion Hazard DANGER When utilizing the gas flush feature optional do not use any gas mixture with greater than 22 oxygen content Blade Hazard WARNING If your machine is equipped with either a Perforating Knife System optional or a Precut Knife System optional then do not remove or install blades without wearing protective gloves These blades are SHARP use care when handli...

Страница 7: ...tend the shelf life of your product you must consult a qualified food technician or specialist to review your application and develop a suitable gas mixture for your package Further you must perform quality control and gas analysis on your final M A P package CLEANING Every environment and application is different thereforeOmcanInc cannot provide cleaning procedure instructions that will guarantee...

Страница 8: ... for the movement of all three types are listed below TC Machines Some of the smallest TC units may be lifted off of their wooden skid and moved manually However Omcan Inc recommends that moving even the smallest of their TC units should not be attempted by one person The larger TC units should be lifted with the aid of a fork lift or other approved lifting aid Prior to lifting with a forklift the...

Страница 9: ...g to the installation checklist described as below z Temperature around 5 40 z Working elevation between 0 1000 meters z Relative humidity 30 95 RH z During operating heat is generated by the vacuum pump and vacuum process so a machine temperature of around 70 80 is normal The machine must have free air access for cooling z A minimum distance from walls other machines etc should be maintained at l...

Страница 10: ...ow is reached Figure 1 2 6 POWER CONNECTION When preparing to install the machine s main power connection please refer to the electrical information on the serial number plate located on the machine s back panel A certified electrician should be employed to complete this connection 2 7 VACUUM PUMP ROTATION If your machine operates on 3 phase power it is important to check the rotation of the vacuu...

Страница 11: ...ded flat plates in the chamber to shorten vacuum time Close the lid to start the cycle the lid will open automatically when cycle is completed Take out the sealed product from vacuum chamber You are ready to start the next cycle After all packaging is completed please let the vacuum pump run for about 15 minutes then turn off the main switch to shut down the machine 3 3 OPTIONAL DEVICE 3 3 1 GAS F...

Страница 12: ...um on the sight gauge Refer to Page 7 2 Replace the oil after 500 hours of operating time C Vacuum Chamber Lid Gasket 1 Check for general wear 2 Check for damage 3 Replace as needed D Pressure Bar Rubber On TC and some SC machines this is the rubber part found in the lid of your machine that meets with the seal bar when the machine is in operation In other SC machines and in all DC machines this i...

Страница 13: ...leaned DO NOT start cleaning until the machine is properly locked out and tagged out 4 2 Vacuum Pump Maintenance For detailed information concerning maintenance and repair of your machine s vacuum pump please refer to the manufactures operating manual that was packaged with your new machine 4 3 Seal Bar Maintenance A Replacing the Teflon Cover 1 Remove the seal bars from your machine a Seal bars a...

Страница 14: ...10 ...

Страница 15: ...xhaust cover or not X Bottom sealing bar working normally or not X Clean the exhaust filter X Change vacuum oil X Replace exhaust filter X Replace Teflon tape X As request Replace sealing Silicone rubber X As request Replace lid gasket rubber X As request Replace pressure bag X As request Replace vanes X Above mentioned maintenance intervals are scheduled basically for 8 working hours per day Reco...

Страница 16: ...cuum pump is rotating in wrong direction Lid silicone rubber damaged Fill oil if necessary Stop machine immediately Then alter the power connection and reconnect to correct ones Replace Insufficient vacuum in bag Note Mostly insufficient vacuum in bag is due to leakage of bag but not the fault of machine Bag is leaking Sharp corners on wrapped product puncture the bag Bag is too large Replace the ...

Страница 17: ... damaged Teflon tape or silicone rubber is damaged Sealing time and cooling time are too short Sealing pressure is too low Heating element is loose Heating element is broken Replace it Tighten it Pressure bar is damaged replace it Replace it Replace it Adjust to proper time Replace the pressure bag Lid does not close Vacuum valve is damaged Limit switch is disconnected or damaged Replace it Reconn...