Omcan RS-CN-0770 Скачать руководство пользователя страница 9

9

Troubleshooting

Trouble

Causes

Solutions

Strange noise under the 

bottom shelf.

Fan blade broken.

Power off and fix the blade.

Non-refrigerating in spite of 

normal operation.

Unit off.

Power on.

Melting process.

Stop melting.

Refrigerant leaking.

Patch the leak and refill refrigerant.

Unit failure.

Call Omcan.

Weak air from air curtain, 

and higher cabinet 

temperature.

Evaporator blocked by frost.

Increase melting frequency.

Inside fan damaged.

Replace the fan.

Too low point of temperature 

controller.

Adjust the set point.

Vent blocked by storage.

Remove the storage.

Normal air curtain, but 

higher cabinet temperature.

Insufficient refrigerant.

Refill the refrigerant.

Too high set point of temperature 

controllers.

Adjust the set point for the 

temperature controller.

The wind curtain disturbed by strong 

air flow.

Removing the disturbing factors.

Ambient temperature or humidity 

beyond standards.

Improve the conditions.

Melting water overflows.

Heating pipe for melting water 

damaged.

Replace the heating pipe.

Water level controller failure.

Replace the water level controller.

Ambient temperature or humidity 

beyond standards.

Improve the conditions.

Maintenance

1.  Cabinet Cleaning: 

a. The product should be maintained and cleaned periodically with power supply disconnected. In cleaning, 

please use mild-rinsing water or non-corrosive products. Do not wash directly with water faucet. 

b. Clean outside of unit using a soft cloth with neutral detergent, and dry with a separate soft cloth. 

c. Clean inside racks by removing them from the unit and clean with water.

2.  When shutting down unit for a long period of time, take out all food and unplug wall socket. Clean inside 

and outside thoroughly, and keep door open to sufficiently dry.

3.  As glass breaks easily, keep far away from children.

4.  Frequently observe the operation of the product. In case of any abnormal noise or smell, cut off the power 

supply immediately and call professionals. Do not restart the product before source of trouble is found.

5.  We will not be responsible for any accidents acquired through failure to follow previous notices.

Содержание RS-CN-0770

Страница 1: ...Revised 01 21 2020 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Refrigerated Showcase Model RS CN 0770 Item 44377 Instruction Manual...

Страница 2: ...e of Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Warranty Registration Mode...

Страница 3: ...NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRE...

Страница 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 5: ...envio Omcan favor inspeccionar da os externos Si no hay da os evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos solicitados sten dentro de la caja y no encuen...

Страница 6: ...any other appliance as cable will overheat and may result in a fire Protect cables Extra caution should be used when handling cables as broken or damaged cables can cause sparking and may result in a...

Страница 7: ...Electrical Heating Element 450 W Lamp Power 8 4 W Number of Shelves 4 Electrical 110V 60Hz 1Ph Dimensions 51 7 x 36 x 63 1313 x 913 x 1597mm Weight 463 lbs 210 kgs Item Number 44377 improper use Plea...

Страница 8: ...onstant the LED is off During delay start the LED flashes 5 Defrost LED During defrosting the LED is on When it stops defrosting the LED is off During the delay of defrost the LED flashed CAUTION Neve...

Страница 9: ...g pipe for melting water damaged Replace the heating pipe Water level controller failure Replace the water level controller Ambient temperature or humidity beyond standards Improve the conditions Main...

Страница 10: ...obe Fault Code EE3 Open circuit or short circuit of overheating probe Check if the plug on the mainboard is loose or not or change the overheating probe Fault Code EE4 Overheating probe starts protect...

Страница 11: ...11 Parts Breakdown Model RS CN 0770 44377...

Страница 12: ...12 Parts Breakdown Model RS CN 0770 44377...

Страница 13: ...393 Pan of High Temperature Pipe for RTS 770L 48 68331 Windshield Clamp for RTS 770L 80 67690 Over Heating Sensor for RTS 770L 17 60652 Pressing Plate of High Pressure Pipe for RTS 770L 49 68380 Saddl...

Страница 14: ...14 Electrical Schematics Model RS CN 0770 44377...

Страница 15: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Страница 16: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: