12
Troubleshooting
Melting water overflown.
Heating pipe for melting water
damaged.
Replace the heating pipe.
Water level controller failure.
Replace the water level controller.
Ambient temperature or humidity
beyond standards.
Improve the conditions.
Normal air curtain, but periodical
fluctuation of cabinet temperature.
Condenser contaminated.
Clean the condenser.
Poor venting of the unit.
Improve the venting conditions.
Heat protection of compressor
failure.
Replace the heat protection.
Capillary is blocked by ice.
Replace the drying filter.
Temperature controller failure.
Replace the temperature controller.
The following situations are not problems:
1. The murmur of water is heard when the refrigerator is working. This is normal as the coolant is circulating in
the system.
2. During wet season, condensation may be found on the outside of the refrigerator. This is not a problem,
this is caused by high humidity. Simply use a cloth to wipe it.
Содержание RS-CN-0468
Страница 13: ...13 Model RS CN 0468 47277 Parts Breakdown...
Страница 14: ...14 Model RS CN 0468 47277 Parts Breakdown...
Страница 16: ...16 Model RS CN 0468 47277 Electrical Schematics...
Страница 17: ...17 Notes...
Страница 18: ...18 Notes...