Troubleshooting
SYMPTOMS
POSSIBLE CAUSE
Compressor will not start
Check if the power cord has been plugged in.
Check for blown fuse.
Maintenance
•
When loading the unit:
- Be careful not to block the air duct located at the back and the fan on the ceiling of the unit with contents.
- Blocking the air flow may cause decrease in performance.
- For the best performance, maintain at least 4 inches of clearance between the contents and the air duct.
• Set the shelves that come with the unit to fit your needs.
•
Temperature controller:
- The controller is located at the right, front corner of the ceiling, or on the front bottom panel.
- To adjust temperature please refer to the manual of temperature controller.
• Do not leave the unit door open for long period of time. For the most efficient operation, close the door
immediately after the use.
ICE ACCUMULATION MAY OCCUR IN FREEzERS
• Try to reduce the amount of time the freezer doors remain open to prevent ice accumulation.
• Keep door seals clean to prevent air leakage.
•
Scrape off any ice accumulated or try manual defrost mode.
Installation
IMPORTANT!!!PLEASE READ BEFORE INSTALLATION
• The refrigeration system operates most efficiently when installed in an area with cool, dry air circulation.
•
There must be at least 6 inches of clearance on both sides and the back of the cabinet.
• Select a location away from the heat and moisture generating equipment such as stoves, ovens, etc.
•
Avoid direct sun rays.
• Be sure that the floor where you intend to install that unit is strong and level enough to support the total
weight of the unit and its contents.
• To minimize shock and fire hazards, be sure that the unit is properly grounded. For your safety and
protection, all units are equipped with a special three-prong grounding plug on the service cord.
• All units are designed for indoor use. Outdoor use may cause significant damage to the unit.
Содержание RE-CN-0045-HC-BK
Страница 17: ...17 Parts Breakdown Model RE CN 0045 HC 50032 Model RE CN 0045 HC BK 51032 ...
Страница 20: ...20 Parts Breakdown Model RE CN 0045 HC SW 52032 Model RE CN 0045 HC SB 53032 ...
Страница 23: ...23 Parts Breakdown Model RE CN 0009 HC 50033 Model RE CN 0009 HC BK 51033 ...
Страница 26: ...26 Model RE CN 0014 H 50035 Model RE CN 0014 HC BK 51035 Parts Breakdown ...
Страница 29: ...29 Model RE CN 0023 HC 50036 Model RE CN 0023 H 50037 Parts Breakdown ...
Страница 32: ...32 Parts Breakdown Model RE CN 0052 HC 50052 Model RE CN 0052 HC BK 51052 ...
Страница 35: ...35 Parts Breakdown Model FR CN 0012 HC 50029 ...
Страница 37: ...37 Parts Breakdown Model FR CN 0790 HC 50030 ...
Страница 39: ...39 Parts Breakdown Model FR CN 1250 HC 50031 ...
Страница 41: ...41 Parts Breakdown Model FR CN 0045 HC 50075 ...
Страница 43: ...43 Parts Breakdown Model FR CN 0052 HC 50087 ...
Страница 46: ...46 Electrical Schematics Model RE CN 0009 HC 50033 Model RE CN 0009 HC BK 51033 ...
Страница 47: ...47 Electrical Schematics Model RE CN 0014 H 50035 Model RE CN 0014 HC BK 51035 ...
Страница 48: ...48 Electrical Schematics Model RE CN 0023 HC 50036 Model RE CN 0023 H 50037 ...
Страница 49: ...49 Electrical Schematics Model RE CN 0052 HC 50052 Model RE CN 0052 HC BK 51052 ...
Страница 50: ...50 Electrical Schematics Model FR CN 0012 HC 50029 ...
Страница 51: ...51 Electrical Schematics Model FR CN 0790 HC 50030 ...
Страница 52: ...52 Electrical Schematics Model FR CN 1250 HC 50031 ...
Страница 53: ...53 Model FR CN 0045 HC 50075 Electrical Schematics ...
Страница 54: ...54 Electrical Schematics Model FR CN 0052 HC 50087 ...