Maintenance

CLEANING THE CONDENSER COIL

•  For efficient operation, it is important that the condenser surface be kept free of dust, dirt and lint.

•  We recommend cleaning the condenser coil and fins at least once per month.

•  Clean with a commercial condenser coil cleaner. Brush the condenser fins from top to bottom, not side to 

side.

•  After cleaning, straighten any bent condenser fins with a fin comb.

CLEANING THE FAN BLADES AND MOTOR

If necessary, clean the fan blades and motor with a soft cloth. If it is necessary to wash the fan blades, cover 

the fan motor to prevent moisture damage.

Installation

CABINET LOCATION GUIDELINES

INSTALL THE UNIT ON A STRONG AND LEVELED SURFACE

• 

Unit may make unpleasant noises if surface is uneven.

• 

Unit may malfunction if surface is uneven.

INSTALL THE UNIT IN AN INDOOR, WELL VENTILATED AREA

•  Unit performs more efficiently in a well ventilated area.

• 

For best performance, please maintain a clearance of 4” from the back of the unit.

• 

Not to be used outdoors.

AVOID INSTALLATION IN A HIGH HUMIDITY AND/OR DUSTY AREA

•  Humidity can cause the unit to rust and decrease efficiency of the unit.

•  Dust collected on the condenser coil will cause the unit to malfunction. Clean the condenser at least once a 

month with a brush or clean cloth.

SELECT A LOCATION AWAY FROM HEAT AND MOISTURE-GENERATING EQUIPMENT

•  High ambient temperatures will cause the compressor to overwork, leading to higher energy bills and 

gradual breakdown of the unit.

ELECTRICAL

Please ensure that the required voltage of the compressor is being supplied at all times. Low or high voltage 

can detrimentally affect the refrigeration unit. All units should be plugged into a grounded a properly-sized 

electrical outlet with appropriate overcurrent protection. Please refer to the electrical requirements on the rating 

plate. Please make sure that your unit has its own dedicated outlet. Do not use an extension cord.

Содержание RE-CN-0041E-HC

Страница 1: ...1 17 2021 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Aurora Refrigeration Models RE CN 0041E HC 0045E HC 0009E HC 0011E HC Items 59026 59032 59033 59056 Instructio...

Страница 2: ...Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty Registration Model RE...

Страница 3: ...T RESPONSIBLE FOR DIMINISHED COOLING OR ANY DAMAGES DUE TO WATER LEAKS WARRANTY IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE DRAIN IS NOT CONNECTED D...

Страница 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 5: ...y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m quina mientras esta en el funcionamiento REVISE EL PAQUE...

Страница 6: ...n Ensure all ventilation openings are unobstructed Caution Servicing shall be done by authorized service personnel so as to minimize the risk of injury due to incorrect parts or improper service ATTEN...

Страница 7: ...the warranty period contact Omcan Inc at 1 800 465 0234 to schedule an Omcan authorized service technician to repair the equipment locally Unauthorized maintenance will void the warranty Warranty cove...

Страница 8: ...82 5 1371 x 818 x 2095mm 53 1 x 31 9 x 79 9 1350 x 810 x 2030mm 21 7 x 21 7 x 63 550 x 550 x 1600mm Interior Dimensions 49 4 x 27 1 x 53 5 1255 x 688 x 1360mm 50 x 28 3 x 61 9 1270 x 720 x 1573mm 18 9...

Страница 9: ...its entirety Technical Specifications UNDER COUNTER REFRIGERATORS Model RE CN 0011E HC Temperature Range 0 5 5 C 32 9 41 F Power 1 4 HP Refrigerant R290 Isolation Material Cyclopentane Cooling System...

Страница 10: ...tly in a well ventilated area For best performance please maintain a clearance of 4 from the back of the unit Not to be used outdoors AVOID INSTALLATION IN A HIGH HUMIDITY AND OR DUSTY AREA Humidity c...

Страница 11: ...denser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make sure thermostat is not set too cold Ensure that the door gaskets are sealing properly Maintena...

Страница 12: ...ed in cabinet Allow adequate time for product to cool down Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker Dirty condenser coil Clean the condenser coil Prolonged door open...

Страница 13: ...13 Model RE CN 0041E HC 59026 Parts Breakdown...

Страница 14: ...AI370 Left Door for 59026 9 AA809 K Strip for 59026 30 AB977 Door Switch for 59026 52 AB032 Upper Left Hinge Holder for 59026 11 AF052 Back Brackets for 59026 31 AF046 Drain Plug for 59026 53 AB033 B...

Страница 15: ...15 Model RE CN 0045E HC 59032 Parts Breakdown...

Страница 16: ...aster without Brake for 59032 11 AE888 Right End Plate for Evaporator for 59032 34 AA686 Plastic Drain Pipe with Fixer for 59032 58 AA584 Caster with Brake for 59032 12 AA863 Fixer for Probe for 59032...

Страница 17: ...17 Model RE CN 0009E HC 59033 Parts Breakdown...

Страница 18: ...tat for 59033 7 AA696 Glass Door for 59033 24 AI386 Compressor for 59033 41 AA216 Drain Tube for 59033 8 AA697 Glass Door Gasket for 59033 25 AA208 Condenser Fan Blade for 59033 42 AA686 Plastic Drain...

Страница 19: ...19 Model RE CN 0011E HC 59056 Parts Breakdown...

Страница 20: ...Evaporator Cover Sticker for 59056 24 AB220 Shelf for 59056 43 AF070 Upper Right Hinge for 59056 8 AF106 Compressor Unit Installation Board for 59056 25 AI371 Evaporator for 59056 44 AI389 Left Door...

Страница 21: ...21 Model RE CN 0041E HC 59026 Electrical Schematics...

Страница 22: ...22 Model RE CN 0045E HC 59032 Electrical Schematics...

Страница 23: ...23 Model RE CN 0009E HC 59033 Electrical Schematics...

Страница 24: ...24 Model RE CN 0011E HC 59056 Electrical Schematics...

Страница 25: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 26: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 27: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Страница 28: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: