Troubleshooting
Problem
Cause
Remedy
Compressor not running.
Fuse blown or circuit breaker
tripped.
Replace fuse or reset circuit
breaker.
Power cord unplugged.
Plug in power cord.
Thermostat set too high.
Set thermostat to lower
temperature.
Cabinet in defrost cycle.
Wait for defrost cycle to finish.
Condensing unit runs for long
periods of time.
Excessive amount of warn product
placed in cabinet.
Allow adequate time for product to
cool down.
Prolonged door opening or door
ajar.
Ensure doors are closed when not
in use. Avoid opening doors for
long periods of time.
Door gasket(s) not sealing
properly.
Ensure gaskets are snapped in
completely. Remove gasket and
wash with soap and water. Check
condition of gasket and replace if
necessary.
Dirty condenser coil.
Clean the condenser coil.
Evaporator coil iced over.
Unplug unit and allow coil to
defrost. Make sure thermostat is
not set too cold. Ensure that door
gasket(s) are sealing properly.
Maintenance
8. Regularly restore/passivate stainless steel.