10
Troubleshooting
Condensing unit runs for long
periods of time.
Excessive amount of warm product
Placed in cabinet.
Allow adequate time for Product to
cool down.
Prolonged door opening or door
ajar.
Ensure doors are closed when not
in use. Avoid opening doors for
long periods of time.
Door gasket(s) not sealing
properly.
Ensure gaskets are snapped in
Completely. Remove gasket and
Wash with soap and water. Check
condition of gasket and Replace if
necessary.
Dirty condenser coil.
Clean the condenser coil.
Evaporator coil iced over.
Unplug unit and allow coil to
Defrost. Make sure thermostat is
not set too cold. Ensure that door
gasket(s) are sealing properly.
Cabinet is noisy.
Loose part(s).
Locate and tighten loose part(s).
Tubing vibration.
Ensure tubing is free from contact
with other tubing or components.
Cabinet Temperature Is too warm. Thermostat set too warm.
Set thermostat to lower
Temperature.
Blocking air flow.
Re-arrange product to allow for
Proper air flow. Make sure there
Is at least four inches of clearance
from evaporator.
Excessive amount of warm product
Placed in cabinet.
Allow adequate time for product to
cool down.
Fuse blown or circuit breaker
tripped.
Replace fuse or reset circuit
breaker.
Dirty condenser coil.
Clean the condenser coil.
Prolonged door opening or door
ajar.
Ensure doors are closed when not
in use. Avoid opening doors for
long periods of time.
Evaporator coil iced over.
(see above)
For service call 1-800-465-0234.
Содержание PT-CN-1270-HC
Страница 14: ...14 Parts Breakdown Model PT CN 1270 HC 50042...
Страница 16: ...16 Parts Breakdown Model PT CN 1829 HC 50043...
Страница 18: ...18 Parts Breakdown Model PT CN 2337 HC 50044...
Страница 20: ...20 Model PT CN 1270 HC 50042 Electrical Schematics...
Страница 21: ...21 Electrical Schematics Model PT CN 1829 HC 50043...
Страница 22: ...22 Electrical Schematics Model PT CN 2337 HC 50044...