7
Maintenance
1. Continuous run times are not advised, allow the machine to rest periodically.
2. After each use, clean the machine, to avoid bacteria growth.
3.
The transmission case is packed with special grease that will last for six months. To add or replace the
grease, it is necessary to remove the upper cover. This should be done by an Omcan authorized provider.
Note: Before maintaining the unit, the machine must be unplugged from the power supply.
Troubleshooting
Trouble
Probable cause
Remedy
The mixing shaft does not rotate
after being turned on.
Electric connectors are loose.
Check the electric circuit, tighten
any loose connectors.
The square rod trembles.
The lock bolts are loose.
Tighten the bolts.
The temperature of the motor rises
beyond normal, or it runs at a
slower speed.
Lack of voltage.
Check the supply voltage.
Over loaded.
Remove some of the product.
The noise of the transmission case
is loud.
Insufficient amount of lubrication.
Add or replace the grease.
The chains are loose.
Tighten the chains.
The agitator hits the bowl in
operation.
The agitator or the bowl is
deformed.
Repair or replace deformed part.
REFERENCE
Item Number Model Number
Description
Manufacturer Model Number
19194
MX-CN-0037
Mixer Spiral Dough 37 QT / 9 GAL 1.1-1.5
HP / 820-1119 W 220V/60/3
HS30DA
19195
MX-CN-0043
Mixer Spiral Dough 43 QT / 11 GAL 1.5-3
HP / 1119-2237 W 220V/60/3
HS40DA
19196
MX-CN-0053
Mixer Spiral Dough 53 QT / 13 GAL 1.5-3
HP / 1119-2237 W 220V/60/3
HS50DA