8
Maintenance
case acid or caustic products.
MAINTENANCE
The machine don’t need any regular maintenance; we remember that, to maintain the machine in excellent
conditions it is enough to perform a scrupulous cleaning at the end of each working cycle.
For unusual maintenances it is advisable to use original spare parts made by the manufacturing company to
avoid any inconvenience due to different manufacturing features. When ordering specify the model and the
serial number of the machine (the serial number is shown both on the tag placed on the machine and on the
cover of this handbook).
ATTENTION
The motor mounted on the meat mixer is equipped with a thermic micro disjunctor, to avoid overheating due to
improper use of the machine. We remember that, to make a good mixture, the maximum kneading time is 10
minutes. If the machine is in operation for 30 continuous minutes, the safety switch will turn off the mixer.
The micro-disjunctor switching on doesn’t stop the machine completely; it causes the machine working
exclusively by impulse controls, to enable the end of the kneading work.
In case of stopping during the work, act as follows:
1. Keep pressing the “AVANTI” button until you reach the desired mixture.
2. Push the “STOP” red button.
3. Unload the tank.
4. Unplug from the socket.
5. Wait for the motor to cool.
6. Switch on again.
ACCIDENTAL STOPPING
If the machine stops accidentally during the processing operation, before investigating the reasons for this
failure, it is necessary to stop at once the supply of electric current to the motor by pushing down the red button
STOP. Then the electric flex should be disconnected from the socket.
After that:
• If the stop is caused by lack of electric current supply due to a failure in the electricity network, do not
reconnect the machine to the socket until normal conditions have been restored in the network.
• In case the inconvenience is due to reasons connected with the power unit, contact the dealer to arrange
for the machine to be checked, if necessary, by the manufacturer.
• If the stop is caused by the thermic micro-disjunctor switching on (due to a motor overheating), wait for the
motor cooling and then switch on again the machine.